Notes
● There may be pipe vibration because Comp circulates the refrigerant with high pressure.
● When Comp vibration is transmitted to Pipe, tightly attach anti-vibration mass on the welding point or
the sharply bended point on the pipe between the pipe and Comp.
Machine-room Pipes contacted
with each other?
EVA container vibrates by Wi-
Con vibration?
Start
Separate the Pipes at the
contacted points.
N
Y
Supplement Sealing material
between Comp Base & EVA
container /
Wi-Con & bottom board.
Y
Pipe vibration severe?
N
Add anti-vibration Mass &
adjust the attachment point.
Y
Comp vibration severe?
N
Attach anti-vibration gum onto
the Comp.
N
Y
Explain to the customer in detail
7-7-5. Pipe Vibration / Interference Noise
55
Содержание Q600 series
Страница 7: ...3 1 Normal Compressor 3 Wiring Diagram 6...
Страница 8: ...3 2 Inverter Compressor 7...
Страница 9: ...4 1 FRQ 19D Dispenser only 4 External Size and Names of the Refrigerator 8...
Страница 10: ...4 2 FRQ 19F Dispenser H bar 9...
Страница 30: ...Contents 3 Ice Separation Mode 29...
Страница 61: ...INVERTER BOX COMPRESSOR 60 INVERTER Compressor VESD11C INVERTER Compressor ENV4A5G L2B...
Страница 101: ...10 4 How to install Water Line Dispenser Models only External Filter Type 100...
Страница 102: ...101...