● General Compressor Wiring
61
OLP
AC power input
Runnging Capacitor
PTC
M
S
C
Average Resistance Value (at Room Temperature)
SUB (Ω)
MAIN (Ω)
18.95 at 35℃
13.25 at 35℃
● COMP or Resistance value CHECKING
-> SUB resistance value = between COMMON & SUB terminal
-> MAIN resistance value = between COMMON & MAIN terminal
=> Normal: SUB & MAIN resistance value checking is possible, and Comp works good when power is
supplied.
=> Abnormal: If SUB & MAIN resistance checking is not possible, and power is not supplied, then it is bad
● Note
The higher the temperature of the coil of the motor is, the larger the resistance will be.
3-2) How to check the bad COMP terminal of a general COMPRESSOR
SUB
MAIN
COMMON