CYCLE(R-600a) Detailed Repair Stage
66
▪
Vacuum pump should be placed at
- Connect the vacuum pum p to the outlet of
discharging hose.
the outdoor which has good ventilation.
▪
It should have enough tim e more than
10 minutes to form a vacuum .
▪
If that is moving freely, it would cause
▪
It should have enough tim e more than
- Discharge Refrigerant R600a
(flammable gas) to outside of a room ,
before connecting the vacuum pump.
7 minutes to discharge.
- Fix the pinch-plier to the com pressor
charging pipe(=
Process Pipe
).
- Pinch-plier should not be moving freely.
Details
fire, explosion as leakage gas in the room.
1
2
Fix the Pinch-plier
&
Charging Pipe
- Connect the inlet of discharging hose
to the pinch-plier.
- The outlet of discharging hose should
be placed to the outdoor
Connect
the Pinch-plier
&
Discharging Hose
3
Remove
Refrigerant
R600a 87%
4
NO
Remove
Refrigerant
R600a 100%
SVC process
Image
outdoor
pinch-plier
Inlet Hose
Outlet Hose