Hardwiring the Hood
, cont.
N1
L1
Neutral (white)
Hot (black)
To junction
Box
Power
Terminals
in Hood
Main Power
Switch Detail
Filter
Wing Nut
Main Power
Switch
Grease
Channel
Filter
Ground
Screw
Back
Bottom
3.
With the provided green screw, attach the ground
wire to the ground screw (next to the main power
switch inside the hood above the filters).
IMPORTANT:
Use a #10 O-ring at the end of the
ground wire.
4.
Remove the wing nut on the main
-
power
-
switch
plate, then remove the plate to access the
terminal block and connect the power wires.
5.
Insert the white wire and black wire through the
plastic hole protector, and tight
en
the wires to
their corresponding terminals.
Junction box
Wire nut
(3 places)
UL/CSA-approved
NEMA strain relief
To range hood
To house circuit
breaker or fusebox
WHITE
WHITE
BLACK
BLACK
GREEN
GREEN
6. Connect the hood wiring to an electrical
junction box or circuit breaker.
WARNING
•
Do not ground the circuit to a gas line or hot-water pipe.
•
Insulated water lines must be jumped to assure continuity to the ground. (See the diagram.)