background image

 

ENGLISH 

 

12 

 

CONTENTS 

WARNINGS .......................................................................................................................................................................................... 12

 

RESPONSIBILITY ................................................................................................................................................................................ 13

 

1

 

GENERAL ................................................................................................................................................................................... 14

 

1.1

 

Applications ....................................................................................................................................................................... 14

 

1.2

 

Pumpable Liquids ............................................................................................................................................................. 14

 

1.3

 

Technical Data ................................................................................................................................................................... 14

 

2

 

INSTALLATION........................................................................................................................................................................... 15

 

2.1

 

Mechanical Installation ..................................................................................................................................................... 15

 

3

 

FIRST INSTALLATION ............................................................................................................................................................... 16

 

4

 

FUNCTION .................................................................................................................................................................................. 17

 

4.1

 

Pump start and stop conditions ...................................................................................................................................... 17

 

4.2

 

Pump On – OFF ................................................................................................................................................................. 17

 

5

 

COM BOX .................................................................................................................................................................................... 18

 

5.1

 

Manual Mode ..................................................................................................................................................................... 18

 

5.2

 

Auto mode ......................................................................................................................................................................... 18

 

5.3

 

COM BOX – DTRON3 Connection ................................................................................................................................... 18

 

5.4

 

How to associate DTRON3 and COM BOX ..................................................................................................................... 18

 

6

 

CLEANING STORAGE MAINTENANCE .................................................................................................................................... 19

 

7

 

TROUBLESHOOTING ................................................................................................................................................................ 19

 

8

 

DESCRIPTION OF COM BOX INTERFACE............................................................................................................................... 20

 

8.1

 

Description of operating mode ........................................................................................................................................ 20

 

8.2

 

Description of LEDs / buttons .......................................................................................................................................... 21

 

9

 

INTERFACE OPERATIVITY ....................................................................................................................................................... 21

 

9.1

 

Passage from Monitor to SETUP mode and vice-versa ................................................................................................ 21

 

9.2

 

Monitor mode .................................................................................................................................................................... 21

 

9.3

 

SETUP mode ...................................................................................................................................................................... 22

 

10

 

COM BOX TROUBLESHOOTING .............................................................................................................................................. 22

 

 

 

KEY 

 

The following symbols have been used in the discussion: 

 

 

SITUATION OF GENERAL DANGER. 

Failure to respect the following instructions may cause damage to persons and property. 

 

SITUATION OF RISK OF ELECTRIC SHOCK.  

Failure to respect the following instructions may cause a situation of serious danger for personal safety. 

 

 

Notes and general information. 

 

WARNINGS 

 

 

 

Read this documentation carefully before installation. 

Installation and operation must comply with the local safety regulations in force in the country in which the product is installed. 

Everything must be done in a workmanlike manner. 

Failure to respect the safety regulations not only causes risk to personal safety and damage to the equipment, but invalidates 

every right to assistance under guarantee. 

 

Skilled personnel 

It is advisable that installation be carried out by competent, skilled personnel in possession of the technical qualifications 

required by the specific legislation in force. 

The term skilled personnel means persons whose training, experience and instruction, as well as their knowledge of the 

respective standards and requirements for accident prevention and working conditions, have been approved by the person in 

charge of plant safety, authorizing them to perform all the necessary activities, during which they are able to recognize and 

avoid all dangers (Definition for technical personnel IEC 364).  

 

The appliance may be used by children over 8 years old and by persons with reduced physical, sensory or mental capacities, or 

Содержание DTron 3

Страница 1: ...Fig Fig Image Abb Afb Fig Obr Kuva Fig Fig ekil Rys bra Fig Fig 1 Fig 2 Fig 3 Fig 5...

Страница 2: ...Fig 6 Fig 7 Fig 8 Fig 9...

Страница 3: ...Fig 10 Fig 11 Fig 12...

Страница 4: ...danger for personal safety Notes and general information WARNINGS Read this documentation carefully before installation Installation and operation must comply with the local safety regulations in forc...

Страница 5: ...he products that it may consider necessary or useful without affecting their essential characteristics who lack experience or knowledge on condition that they are under supervision or after they have...

Страница 6: ...nly use the pump in clean water The pump must not be used to pump salt water sewage inflammable corrosive or explosive liquids e g petroleum petrol thinners greases oils The temperature of the liquid...

Страница 7: ...r with I n 30 mA and that the earth system is efficient Any extension cables comply with the regulations in force 2 1 Mechanical Installation Install the pump in a location that is not exposed to free...

Страница 8: ...ve protects the pump from breakage Installation in a well Install the pump so that the pump suction is at least 1 m 3 28ft above the bottom of the well to prevent the intake of sand and impurities Use...

Страница 9: ...ressure above the CUT IN The pump stops even when there is no water safeguarding the motor see ANTI DRYRUN function Various alarms 4 2 Pump On OFF The pump motor is powered by the electronic control b...

Страница 10: ...scribed here is also effective if starting is set to Manual mode 5 2 Auto mode In this mode the pump power supply is supplied to the motor according to the evolution of the user s requirements and the...

Страница 11: ...e the plug out of the socket If the power cable or any electrical part of the pump is damaged the repair or replacement must be carried out by the manufacturer or by their technical assistance service...

Страница 12: ...e in MONITOR mode pressure on the delivery of the DTRON3 pump 6 motor power status 4 DISABLE status of the pump XX current faults alarms 5 8 10 11 connection status of the COM BOX with the DTRON s 8 T...

Страница 13: ...ons Figure 12 2 and Reset Select Figure 12 3 simultaneously for at least 3 seconds or wait for 1 minute without touching any button on the interface When switched on the COM BOX is in Monitor mode by...

Страница 14: ...resented in the barometric scale by flashing Instead the current value of the CUT IN is highlighted with the corresponding LED lit with a steady light Too low a CUT IN value could prevent the pump tur...

Отзывы: