PUMP BLOCK function 

By simultaneously pressing and releasing the "+" and "-" buttons (fig 12, 1 - 2), the pump motor stops unconditionally and cannot start again 

until the "+" and "-" buttons (fig 12, 1 - 2) are pressed again simultaneously and released. This Inhibition also prevails over any motor start set in  

"MANUAL” mode. 

The blocking of the pump stops if DTRON3 and COM BOX are disconnected. Turning on the DTRON3 again or the absence of connection 

between DTRON3 and COM BOX does not affect the setting of the inhibition. 

 

ALARM RESET function 

The alarms can be set manually by pressing the ”Reset/Select” button (Figure 12, 3). 

 

9.3

 

SETUP mode 

Once in SETUP mode (see paragraph 8.1) 

With the exception of the CUT-IN function, the activation of each function causes the corresponding LED to light up, which will flash as 

described below:  

 

ON x 3 sec  

 

Flashing 0.3 sec ON and Off, 4 times 

SETTINGS SELECTION mode 

With the "Reset/Select" button (Figure 12, 3) you can go through the settings described below.  

The first setting you will find, once the SETUP Mode is activated, is the "CUT-IN Variation". 

 

CUT-IN Variation 

With this function it is possible to vary the pump CUT-IN value. This value can be increased/decreased with the "+" and "-" buttons (Fig 12, 1-2) 

and can assume the values represented in the barometric scale by flashing. 

Instead, the current value of the CUT-IN is highlighted with the corresponding LED lit with a steady light. 

 

 

Too low a CUT-IN value could prevent the pump turning on and keep it off at all times. 

Too high a CUT-IN value could cause a DRYRUN alarm. 

It is recommended not to exceed the CUT-IN value of: 

•  2.5 bar (36.2 psi) for models DTRON3 (X) 35/90 and 35/120  

•  3.5 bar (50.7 psi) for models DTRON3 (X) 45/120  

 

 

Enabling/disabling manual operation 

In this setting, the pump motor is switched on using the "+" button (Fig 12, 1). 

The "-" button (Fig 12, 2) restores normal operating conditions. 

 

Associating/Dissociating COM BOX / DTRON3 

In this setting, by pressing the "+" button (Fig 12, 1) for 5 seconds, the COM BOX temporarily enters the PLC association status through the 

power supply network. 

Pressing the "-" button (Fig 12, 2) for 5 seconds eliminates any association with the DTRON3. 

 

Enabling/disabling ANTICYCLING 

In this setting, use the "+" button (Fig 12, 1) to activate the ANTICYCLING function described above. 

The "-" button (Fig 12, 2) deactivates this function. 

 

10

 

 

COM BOX TROUBLESHOOTING 

FAULTS 

PROBABLE CAUSES 

REMEDIES 

The Pump and the COM BOX do 

not connect to each other 

1. They are galvanically separated 

1. Check that the two units are on the same power 

supply and in the same phase. 

2. They are too far apart 

2. Connect the two units at a shorter distance 

3. The two units are not associated 

3. Repeat the first association procedure described in 

8.3. 

 

Содержание DTron 3

Страница 1: ...Fig Fig Image Abb Afb Fig Obr Kuva Fig Fig ekil Rys bra Fig Fig 1 Fig 2 Fig 3 Fig 5...

Страница 2: ...Fig 6 Fig 7 Fig 8 Fig 9...

Страница 3: ...Fig 10 Fig 11 Fig 12...

Страница 4: ...danger for personal safety Notes and general information WARNINGS Read this documentation carefully before installation Installation and operation must comply with the local safety regulations in forc...

Страница 5: ...he products that it may consider necessary or useful without affecting their essential characteristics who lack experience or knowledge on condition that they are under supervision or after they have...

Страница 6: ...nly use the pump in clean water The pump must not be used to pump salt water sewage inflammable corrosive or explosive liquids e g petroleum petrol thinners greases oils The temperature of the liquid...

Страница 7: ...r with I n 30 mA and that the earth system is efficient Any extension cables comply with the regulations in force 2 1 Mechanical Installation Install the pump in a location that is not exposed to free...

Страница 8: ...ve protects the pump from breakage Installation in a well Install the pump so that the pump suction is at least 1 m 3 28ft above the bottom of the well to prevent the intake of sand and impurities Use...

Страница 9: ...ressure above the CUT IN The pump stops even when there is no water safeguarding the motor see ANTI DRYRUN function Various alarms 4 2 Pump On OFF The pump motor is powered by the electronic control b...

Страница 10: ...scribed here is also effective if starting is set to Manual mode 5 2 Auto mode In this mode the pump power supply is supplied to the motor according to the evolution of the user s requirements and the...

Страница 11: ...e the plug out of the socket If the power cable or any electrical part of the pump is damaged the repair or replacement must be carried out by the manufacturer or by their technical assistance service...

Страница 12: ...e in MONITOR mode pressure on the delivery of the DTRON3 pump 6 motor power status 4 DISABLE status of the pump XX current faults alarms 5 8 10 11 connection status of the COM BOX with the DTRON s 8 T...

Страница 13: ...ons Figure 12 2 and Reset Select Figure 12 3 simultaneously for at least 3 seconds or wait for 1 minute without touching any button on the interface When switched on the COM BOX is in Monitor mode by...

Страница 14: ...resented in the barometric scale by flashing Instead the current value of the CUT IN is highlighted with the corresponding LED lit with a steady light Too low a CUT IN value could prevent the pump tur...

Отзывы: