ENGLISH
53
14.
INDICATIONS ON THE DISPLAY
Identifying s.
Description
Factory parameters
Indications on the display in normal operation
A.D.
M/M 1.1
A.D.
M/T 1.0
A.D.
M/T 2.2
A.D.
T/T 3.0
A.D.
T/T 5.5
Go Electropump
operating
Sb Electropump
waiting
User displays and settings
(keys MODE and SET 2 seconds )
SP
Setting the set-point pressure ( in bar ). Default: 3 bar
3.0 bar
3.0 bar
3.0 bar
3.0 bar 3.0 bar
Installer displays and settings
(keys MODE and SET and – 5 seconds )
rC
Setting the rated current of the electropump ( in A )
rt
Setting the direction of rotation
00
00
00
00
Fn
Setting the rated rotation frequency of the electropump.
( in Hz )
50 50 50 50
50
od
Setting the operating mode
01
01
01
01
01
rP
Setting the pressure drop for restarting ( in bar )
0.5 bar
0.5 bar
0.5 bar
0.5 bar 0.5 bar
Ad
Setting the interconnection address
(necessary on sets of several electropumps with exchange)
“- -”
“- -”
“- -”
“- -”
Eb
Enabling the booster
02
02
02
02
Technical assistance displays and settings
(keys MODE and SET and + 5 seconds )
tb
Setting the reaction time of the water lack blockage ( in s. )
10 s
10 s
10 s
10 s
10 s
GP
Setting the gain of the proportional coefficient of the PI
1.0
1.0
1.0
1.0
1.0
GI
Setting the gain of the integral coefficient of the PI
1.0 1.0 1.0 1.0
1.0
FS
Setting the maximum rotation frequency of the electropump
( in Hz )
50 50 50 50
50
FL
Setting the minimum rotation frequency of the electropump.
( in Hz )
0 0 0 0
0
Ft
Setting the low flow rate threshold
15
15
15
15
15
CM
Exchange method on sets of 2 electropumps
01
01
01
01
AE
Setting the enabling of the anti-block/anti-frost function
01 01 01 01
01
SF
Setting the starting frequency
45
St
Setting the starting time
1.0
i 1
Setting the function of input 1 (float)
01
01
01
i 2
Setting the function of input 2 (set point selection)
01
01
01
i 3
Setting the function of input 3 (enable )
01
01
01
P1
Setting the auxiliary setpoint pressure (in bar)
- in function of input 2 -
2.5 bar
2.5 bar 2.5 bar
o1
Setting the function of output 1 (default value: 2; function: ON alarm )
02
02
02
o2
Setting the function of output 2 (default value: 2; function: ON operating )
02
02
02
Displays of the main values
(MODE key)
Fr
Display of the current rotation frequency (in Hz)
UP
Display of pressure (in bar)
C1
Display of the phase current of the electropump (in A)
UE
Display of the version of the software with which the appliance is
equipped
DISPLAY (keys SET and – for 2 seconds )
UF
Display of the flow
ZF
Display of zero flow
FM
Display of the maximum rotation frequency (in Hz)
tE
Display of the temperature of the power stages (in °C)
bt
Display of the temperature of the electronic card (in °C)
GS
Display of running status
FF
Display of the log of errors and blockages
Access to manual mode
(keys SET and + and – 5 seconds )
FP
Setting the test frequency in manual mode (in Hz)
≤
the set value FS
40 40 40 40
40
UP
Pressure display (in bar)
C1
Display of electropump phase current (in A)
rt
Setting the direction of rotation
UF
Display of flow
ZF
Display of zero flow
System reset
(keys MODE and SET and + and – )
ZF
General reset ( ZF appears when leaving reset and restarting )