DGS-3200 Series Layer 2 Gigabit Managed Switch CLI Manual
420
2 5 5 . 2 5 5 . 2 5 5 . 2 5 5 2 5 5 . 2 5 5 . 2 5 5 . 0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
A c c e s s I D : 1 M o d e : P e r m i t R X R a t e ( 6 4 K b p s ) : n o _ l i m i t
P o r t s : 1
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
d e f a u l t 2 0 . 2 . 2 . 3 1 0 . 1 . 1 . 0 3
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
U n u s e d E n t r i e s : 1 9 9
D G S - 3 2 0 0 - 1 0 : 4 #
46-5 config time_range
Purpose
Used to configure the range of time to activate a function on the switch.
Format
config time_range <range_name 32> [ hours start_time < hh:mm:ss > end_time< hh:mm:ss >
weekdays <daylist> | delete]
Description
This command defines a specific range of time to activate a function on the Switch by specifying which
time range in a day and which days in a week are covered in the time range. Note that the specified time
range is based on SNTP time or configured time. If this time is not available, then the time range will not be
met.
Parameters
Parameters
Description
range_name
Specifies the name of the time range settings.
start_time
Specifies the starting time in a day. (24-hr time)
For example, 19:00 means 7PM. 19 is also acceptable.
start_time
must be smaller than end_time.
end_time
Specifies the ending time in a day. (24-hr time)
weekdays
Specify the list of days contained in the time range. Use a dash
to define a period of days. Use a comma to separate specific
days. For example,
mon-fri
(Monday to Friday)
sun, mon, fri
(Sunday, Monday and Friday)