xStack® DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch Web UI Reference Guide
10
Shutdown
Specifies whether to shutdown the port, when the operating parameter exceeds the
Alarm
or
Warning
threshold.
Click the
Apply
button to accept the changes made for each individual section.
Click the
Reload Threshold
button to reset the threshold configuration to default.
DDM Temperature Threshold Settings
This window is used to configure the DDM Temperature Threshold Settings for specific ports on the Switch.
To view the following window, click
System
Configuration > Port Configuration > DDM > DDM Temperature
Threshold Settings
, as shown below:
Figure 2-6 DDM Temperature Threshold Settings window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the unit to be configured.
(EI Mode Only)
From Port / To Port
Select a range of ports to be configured.
High Alarm (-128-
127.996)
This is the highest threshold for the alarm. When the operating parameter rises above
this value, action associated with the alarm will be taken.
Low Alarm (-128-
127.996)
This is the lowest threshold for the alarm. When the operating parameter falls below this
value, action associated with the alarm will be taken.
High Warning (-
128-127.996)
This is the highest threshold for the warning. When the operating parameter rises above
this value, action associated with the warning will be taken.
Low Warning (-
This is the lowest threshold for the warning. When the operating parameter falls below
Содержание xStack DGS-3120 Series