24
SETUP
2ND LEVEL
3RD LEVEL
5 min
10 min
Auto Source
(Switcher mode only)
On
OFF
Telnet TimeOut
OFF
1~10 mins
Firmware Update
NO
Yes
User EDID Reset
NO
Yes
Factory Reset
NO
Yes
1) Auto Sync Off: Set the amount of time to continue outputting sync
with a black screen if there are no live sources and no operations have
been executed on the unit. Setting this to “Always On” forces the unit
to always output sync.
2) Auto Source: Enable or disable input source auto switching.
Note: Only available in the Scaling mode’s Switcher mode.
3) Telnet TimeOut: Set the length of time to wait for activity over a
Telnet connection before automatically disconnecting the session.
4) Firmware Update: To update the firmware via USB, select “Yes” and
then insert a USB stick containing the new firmware into the Service
port. The upload will occur immediately.
Note: The USB stick must contain, in the root directory, a compatible and
properly named (*.bin) firmware file.
5) User EDID Reset: Select “Yes” to reset the unit’s User EDIDs to their
factory default states.
6) Factory Reset: Select “Yes” to reset the unit to its factory default state.
After the reset is complete, the unit will reboot automatically.