33
COMMAND
Description and Parameters
set_cond N1 -- N2 N3
Set a temporary min/max value range for the specified Condition port(s)
and decrease the stored value by 1.
N1
= 1~64
[Condition port number]
N2
= 0~255
[Adjustment minimum value]
N3
= 0~255
[Adjustment maximum value]
Note: Multiple values may be entered for N1, N2 and N3 by separating
the values with commas. All 3 sets must have the same number of
values.
set_cond N1 led N2 N3
Bind the color of the specified button’s LED to the specified Condition
port’s value.
N1
= 1~64
[Condition port number]
Available values for
N2
:
0
[Disable LED condition check]
1~15
[Button LED pair to control]
Available values for
N3
:
TRUE
[Set LED to RED on “1” or BLUE on “0”]
FALSE
[Set LED to RED on “0” or BLUE on “1”]
Note: Multiple values may be entered for N1, N2 and N3 by separating
the values with commas. All 3 sets must have the same number of
values.
get_cond
List the current state of all Condition ports.
Note: Commands will not be executed unless followed by a carriage return.
Commands are not case-sensitive.
Содержание CDPW-K1
Страница 1: ...Operation Manual Operation Manual CDPW K1 15 Button Control Keypad CDPW K1S 9 Button Control Keypad...
Страница 2: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ...CYPRESS TECHNOLOGY CO LTD www cypress com tw...