Factory settings: Master code = 1111 Buzzer active Opening the pushbutton: NO
No user code
Release control: pulse
Release tempo = 5 seconds
Access status: protected
Keypad not locked if incorrect code entered
Activation of programming mode : Enter the master code twice and confirm with the # key. The keypad switches to programming mode and the red and green indicators flash alternately. Automatic exit from programming mode if no key is depressed for a period of 60 seconds.
Master code : The master code is the entry key for all possible modifications. Only the system administrator may know the master code. The master code consists of 4 to 8 numbers the default master code is «1111». For security reasons, the master code must be changed.
Changing the master code:
activate programming mode,
press 1 *,
enter the new master code (4 to 8 numbers) and
confirm with #. A confirmation beep will sound. Quit the programming mode by pressing #.
Example of changing the master code «1111» via «123456»: 1111 1111 # 1 * 123456 # #
Learning of one or several user codes :
Activate programming mode and
enter the order number for the user code to be created (00 to 99),
enter the user code (4 to 8 numbers),
confirm with #. A confirmation beep confirms the learning. Restart operations
to
to teach in a new code or exit programming mode by pressing #.
Example, teach in user code 12548: 1111 1111 # 04 12548 # #
Deleting one or more user codes :
Activate programming mode and
enter the order number for the user code to be deleted (00 to 99),
confirm with #. A confirmation beep confirms deletion of the user code. Restart operations
to
to delete another code or exit programming mode by pressing #
Example, deletion of user codes 02 and 12: 1111 1111 # 02 # 12 # #
Deleting all user codes :
Activate programming mode,
press 5 * 0,
confirm with #. A confirmation beep confirms the deletion of all user codes. Quit the programming mode by pressing #.
Example: 1111 1111 # 5 * 0 # #
Controlling the release :
Activate programming mode,
press 2 *,
enter 000 (bi-stable mode 0 <---> 1) or 001 to 255 (pulse mode) for a period ranging between 001 and 255 seconds,
confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example, 15 second period: 1111 1111 # 2 * 015 # #
Disabling/enabling the buzzer :
Activate the programming mode,
press 4 *,
enter 0 for disabled or 1 for enabled,
confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example, disabled: 1111 1111 # 4 * 0 # #
Pushbutton open :
Activate programming mode,
press 6 *,
enter 0 for NO or 1 for NC,
confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example of NC: 1111 1111 # 6 * 1 # #
Keypad locked following 5 successive entries of the incorrect code :
Activate programming mode,
press 7 *,
enter 0 for a disabled lock or 1 to 9 for an enabled lock for 1 to 9 minutes,
confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing # .
Example of a 5 minute lock: 1111 1111 # 7 * 5 # #
Configuring free access :
Activate programming mode,
press 8 *,
enter 0 for protected access or 1 to 98 for free access for 1 to 98 hours or 99 for permanent free access,
confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example of free access for 4 hours: 1111 1111 # 8 * 4 # #
Restore to factory settings except for user codes and master code :
Activate programming mode,
press 5 * 2,
confirm with #. A confirmation beep confirms the deletion of all user codes. Quit the programming mode by pressing #.
Example: 1111 1111 # 5 * 2 # #
Restore factory settings for all data :
Activate programming mode,
press 5 * 1,
confirm with #. A confirmation beep confirms the deletion of all user codes. Quit the programming mode by pressing #.
Example: 1111 1111 # 5 * 1 # #
Restore factory settings without master code : Keep pushbutton 1 (BP 1) and pushbutton 2 (BP 2) depressed, release pushbutton 2, wait 10 seconds for the double confirmation beep, then release pushbutton 1
Safety
instructions
This product should be installed in compliance with installation rules, preferably by a qualified electrician.
Incorrect installation and use can lead to risk of electric shock or fire.
Before carrying out the installation, read the instructions and take account of the product’s specific mounting location.
Do not open up, dismantle, alter or modify the device except where specifically required to do so by the instructions.
All Legrand products must be opened and repaired exclusively by personnel trained and approved by Legrand.
Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees.
Use only Legrand brand accessories.
3
4 5
6
7 8
2
1
9
0 #
Self-contained keypad
5 722 52 / 5 727 52
LE01483AC
U
Ι
max.
1N4007
-
+
1N4007
-
+
~
IP
IK
C
T
R
IP
IK
~
IP
IK
C
T
R
~
IP
IK
C
T
R
~
IP
IK
C
T
R
~
IP
IK
C
T
R
~
IP
IK
C
T
R
12 V
~
IP
IK
C
T
R
24 V
~
IP
IK
C
T
R
70 mA
45 mA 12 V 2 A
24 V 2 A
48 V 1,2 A
IP 30
IK 04
- 10° C
+ 55° C
≥ 40 mm
5 U
> 0,90 m
< 1,30 m
100
12 V
~
IP
IK
C
T
R
24 V
~
IP
IK
C
T
R
35 mA
20 mA
LED D1 D0 - +
C T R
BP1
BP2
(+) 12 / 24 V
(-) 0 V
~
IP
IK
C
T
R
LED D1 D0 - +
C T R
BP1
BP2
3
2
1
4
8 mm