Installing the Singlewire InformaCast Indoor Intercom with Keypad
Configure the Events Parameters
Operations Guide
931640A
CyberData Corporation
82
2. On the
Events
page, enter values for the parameters indicated in
.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the
Toggle Help
button is pressed
.
Table 2-23. Events Configuration Parameters
Web Page Item
Description
Enable Event Generation
The device will send HTTP POST events to the specified remote server and port
number whenever a certain action takes place. Select an event type below to
generate an HTTP POST event.
Events
Enable Button Events
When selected, the device will report Call button presses.
Enable Call Start Events
When selected, the device will report the start of a SIP call.
Enable Call Terminated Events
When selected, the device will report the end of a SIP call.
Enable Relay Activated Events
When selected, the device will report relay activation.
Enable Relay Deactivated Events
When selected, the device will report relay deactivation.
Enable Ring Events
When selected, the device will report when it starts ringing upon an incoming SIP
call. A Ring Event will not be generated when
Auto-Answer Incoming Calls
is
enabled on the
Device
page.
Enable Night Ring Events
When selected, the device will report when it starts ringing upon an incoming SIP
call to the Nightringer extension. As a reminder, the Nightringer extension always
rings upon an incoming SIP call and it is not possible to alter this behavior.
Enable Multicast Start Events
When selected, the device will report when the device starts playing a multicast
audio stream.
Enable Multicast Stop Events
When selected, the device will report when the device stops playing a multicast
audio stream.
Enable Power On Events
When selected, the device will report when it boots.
Enable Sensor Events
When selected, the device will report when the on-board sensor is activated.
Enable Remote Relay Events
When selected, the device will report when the remote relay (DSR) is activated.
Enable Security Events
When enabled, the device will report when the intrusion sensor is activated.
Enable 60 Second Heartbeat Events
When enabled, the device will report a Heartbeat event every 60 seconds. SIP
registration is not required to generate Heartbeat events.
Enable Informacast Start Events
When selected, the device will report when a Start event has been received from
the Singlewire server.
Enable Informacast Stop Events
When selected, the device will report when a Stop event has been received from
the Singlewire server.
Check All
Click on
Check All
to select all of the events on the page.
Uncheck All
Click on
Uncheck All
to de-select all of the events on the page.
Event Server
Server IP Address
The IPv4 address of the event server in dotted decimal notation.
Server Port
Specify the event server port number. The supported range is 0-65536. Enter up to
5 digits.
Server URL
Generally, the destination URL is the name of the application that receives the
events and the string in the HTTP POST command. It can be a script used to parse
and process the HTTP POST events. Enter up to 127 characters.