Installing the Singlewire InformaCast Indoor Intercom with Keypad
Wiring the Circuit
Operations Guide
931640A
CyberData Corporation
15
2.3.3.3 Network Dual Door Strike Relay Wiring Diagram Using PoE+
Figure 2-9. Network Dual Door Strike Relay Wiring Diagram Using PoE+
If you have questions about connecting door strikes or setting up the web configurable options,
please contact our support department at the following website:
Sense Input 2
Aux Button 2
Sense Input 1
Aux Button1
Doo
r S
trike
*
Doo
r S
trike
*
802.3at Compliant Ethernet Switch
Internal 12VDC
source (500 mA
maximum)
GENERAL ALERT
*Caution
Equipment Hazard:
The door strike must have an internal or external mov or
diode (for over voltage protection) when connecting directly to the module.
See the Network Dual Door Strike Relay
Operations Guide for connection specifics.
Section 2.4.16, "Configure the Door Strike
for configuration options.
CyberData
Device
The relay connection maximum wire
size is 12 gauge stranded wire.