Installing the Singlewire InformaCast Indoor Intercom with Keypad
Configure the Security
Operations Guide
931640A
CyberData Corporation
44
2. On the
Security
page, you may enter values for the parameters indicated in
.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the
Toggle Help
button is pressed
.
Table 2-12. Security Configuration Parameters
Web Page Item
Description
Security Settings
ID
Displays the ID associated with this security record.
Name
Displays the name associated with this security record.
Code
Displays the security code associated with this security record.
Valid From
Section 2.4.7.2, "The “Valid From” and “Valid To” Settings"
.
Valid To
Section 2.4.7.2, "The “Valid From” and “Valid To” Settings"
.
Blacklist
Displays the Blacklisted status of this security record. Blacklist is used to deny
entry to the specified security code. Entering a blacklisted code will trigger the
buzzer, and can trigger a call to an extension or a multicast of a pre-recorded
message.
Opens the
. See
.
Removes the security code record.
Opens a new Configure Security Code window.
Relay Settings
Activate Relay on Valid Code
Activates the relay when a valid code is entered. This would likely be used to
open a door.
Activate DSR on Valid Code
Activates the remote relay when a valid code is entered. This would likely be
used to open a door.
Relay Timeout (seconds)
Specifies how many seconds the relay will be activated after a valid code
entry. In a typical use case, this would specify how long the door is unlocked.
Audio Settings
Play tone while Relay Active
When selected, an audible tone will indicate the relay is active.
Play tone on Invalid Code Entry
When selected, a tone will play on the speaker to indicate an invalid code was
entered.
Sensor Settings
Buzz on Door Open Timeout
When selected, the buzzer will beep until the on board sensor is deactivated.
Door Sensor Normally Closed
Select the inactive state of the door sensor. The door sensor is also known as
the Sense Input on the device's terminal block.
Sensor Open Timeout (in seconds)
The time (in seconds) the device will wait before it triggers the buzzer when
the door sensor is active.
DSR Open Timeout (in seconds)
The time (in seconds) the device will wait before it triggers the buzzer when
the remote door sensor (DSR) is active.