Installing the Singlewire InformaCast Indoor Intercom with Keypad
Configure the Sensor Configuration Parameters
Operations Guide
931640A
CyberData Corporation
73
Slow Blink
Strobe will blink ON at the specified brightness for one second
then OFF for one second during the duration of the event.
Fast Blink
Strobe will blink ON at the specified brightness then OFF five
times per second during the duration of the event.
Color
Select desired color (only one may be chosen).
Brightness
How bright the strobe will blink when the sensor is triggered. This
is the maximum brightness for “fade” type scenes.
Red
The red LED value for the Sensor.
Green
The green LED value for the Sensor.
Blue
The blue LED value for the Sensor.
Use this button to preview the strobe flashing behavior for the
Sensor Strobe Settings
.
Intrusion Sensor Settings
Flash Button LED
When selected, the Call button LED will flash until the intrusion
sensor is deactivated (roughly 10 times/second).
Activate Relay
When selected, the device's on-board relay will be activated until
the intrusion sensor is deactivated.
Play Audio Locally
When selected, the device will loop an audio file out of the
speaker until the intrusion sensor is deactivated.
Make call to extension
When selected, the device will call an extension when the
intrusion sensor is activated. Use the
Dial Out Extension
field
below to specify the extension the device will call.
Dial Out Extension
Specify the extension the device will call when the intrusion
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID
An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Play recorded audio
When selected, the device will call the
Dial Out Extension
and
play an audio file (corresponds to
Intrusion Sensor Triggered
on the
Audiofiles
page) to the phone answering the SIP call
when the intrusion sensor is activated.
Repeat Intrusion Message
The number of times to repeat the audio message through the
local speaker or to the remote endpoint. A value of 0 will repeat
forever. Enter a value from 0-65536.
Intrusion Sensor Strobe Settings
The following strobe settings will only appear if a CyberData
Strobe product is connected to your device. If a CyberData
Strobe product is not connected to your device, you will not
see the strobe settings.
Blink Strobe on Intrusion Sensor
When selected, the Strobe will blink a scene when the intrusion
sensor is triggered.
Scene
Select desired scene (only one may be chosen).
ADA Compliant
Strobe will blink ON at the specified brightness for 150ms then
OFF for 350ms during the duration of the event.
Table 2-21. Sensor Configuration Parameters (continued)
Web Page Item