Local port:
This parameter sets the local server port TCP/UDP. (Between 1024 and 65535)
Remote IP:
This parameter is the Admin remote IP Address. Not Bundle IP address.
Remote Port:
This parameter sets the remote server port TCP/UDP. (Between 1024 and 65535)
RS-485 / RS-232:
This parameter is always RS-232 on this equipment.
5.3.13.
System status
This page shows factory information of the CIP-ALL with the detail of its cards (LLA, FXO, FXS, EM), MAC Address, and Serial Number.
5.3.14.
E1 status
This page shows E1 status information of the CIP-ALL with the detail of the different alarms.
•
LOS
Loss of Signal: when the E1 port has a loss of signal. This alarm is available for unframed or framed configuration. Check the
cable connection to the E1 link connector.
•
LOF
Loss of Frame:
available for framed configurations when the synchronization is poor; i.e. time slot 0 not synchronized, CRC4
errors.
•
AIS
Alarm Indication: available on the unframed mode when the received signal is AIS.
•
RAI
Remote Alarm Indication: available on framed configurations when the remote CIP has a problem.
•
Frame Slip:
E1 frame slips are being detected during loss of frame synchronization, updated once per second. Verify the clock
settings.
•
Code violations (BVP):
coding error or bipolar violations on the link receive signal, i.e. the E1 line receives perturbations or E1 line is
too long. Verify cable connecting.