![CXR CIP-2ALL Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cxr/cip-2all/cip-2all_user-manual_2701290003.webp)
User manual
CIP-ALL
CIP-ALL
- Page 3
Quick start Guide
Connections
•
Connect the analog equipment on the RJ45 ports: telephone, modem, RTU …
o
NOTE: If a 75 ohm coaxial termination using the BNC connectors is required for E1 use, an internal jumper must be
changed. See page last annex, E1 port.
•
Connect the Ethernet port to the WAN or LAN.
•
Connect the green connector power on the right side of the product:
o
Two ‘+’ inputs and one ‘-‘ input : 36 to 72 Vdc isolated power supply.
o
Protection (frame) Ground
•
Connect a Personal Computer to an Ethernet port for setting up the product
Web Interface
The factory default IP address is: 192.168.1.1
Configure the Computer IP address: 192.168.1.11 and netmask: 255.255.255.0
Connect the CIP-ALL and the PC on the same LAN.
Fill user login
admin
and password
admin
.
Create a Bundle between two CIP-ALL products
A Bundle is a number of parameters to establish a link between two user interfaces through the CIP-ALL. Here is an example of two Leased
Line modems connected to the analog port of each CIP-ALL:
Option
E1
Analog Equipment:
modem, phone
WAN or LAN IP
LAN 1-2-3-3
PC, IP Ethernet Port
address: 192.168.1.1
+ + - GND
RS232
Term
Console
Alarm
Содержание CIP-2ALL
Страница 5: ...User manual CIP ALL CIP ALL Page 5...