VacuStar W900 / W1300 / W1600
Technical data
17
3
Technical data
VacuStar W operating data
Unit
Model
W900
Model
W1300
Model
W1600
Speed range
[min
–1
]
1000…1500
Nominal operating vacuum
[mbar]
400
400
400
Permissible continuous duty vacuum
1
[mbar]
100
100
100
Maximum final overpressure during compressor
operation in case of direct drive
2
[bar]
2
2
2
Maximum final overpressure during compressor
operation in case of V-belt drive
2
[bar]
2
1.5
0.5
Oil reservoir
[l]
7.5
7.5
7.5
Lubricating oil consumption
[l/h]
0.2
0.3
0.4
Weight (without accessories)
[kg]
220
279
339
Tab. 1: Operating data
Lubricating oils
The use of multigrade oils will damage the VacuStar W. In that case, the
warranty on the part of CVS Engineering GmbH shall cease.
Only single grade oils with the following specification are permitted for
operating the VacuStar W:
Specification
Value
API:
CF/CF4 or higher
ACEA:
E2 or higher
Tab. 2: Lubricating oils
Lubricating oil types
Recommendations
Brand
Suction temp. > 10 °C
Suction temp. < 10 °C
ARAL
Basic Turboral SAE 40
Basic Turboral SAE 30
BP
Vanellus C3-40
Vanellus C3-30
FUCHS
Titan Universal HD 40
Titan Universal HD 30
MOBIL
Delvac 1340
Delvac 1330
Delvac 1640
Delvac 1630
SHELL
Rimula X Monograde 40
Rimula X Monograde 30
Tab. 3: Lubricating oil types
ATTENTION!
Do not use any synthetic lubricants!
1
Only in conjunction with cell ventilation, without cell ventilation 200mbar (protection via ventilation valve)
2
Protection via a safety valve
Содержание VacuStar W1300