VacuStar W900 / W1300 / W1600
Maintenance
27
7.3 Performance of maintenance work
Cleaning the VacuStar W
Carrying out cleaning work:
1.
Switch off system and secure against restarting.
2.
Remove soiling appropriately. Observe the following:
Do not use aggressive cleaning agents.
Pay attention during cleaning that no water gets into the
compression chamber.
Exercise special caution when cleaning with high-pressure
cleaning systems.
Absorb oil deposits with oil-absorbing materials (e.g. sawdust).
After cleaning work, check that all previously opened covers
and safety equipment are correctly installed and function
correctly.
After wet cleaning, warm up the VacuStar W for a few minutes.
Water cooling system /cleaning the
radiator
Check cooling water level in compensation reservoir and top up if
necessary.
Clean radiator in case of soiling as the cooling air must have free
passage.
Action after lengthy standstill
If the standstill of the VacuStar W installed inside the vehicle lasts
for more than a month, we recommend putting the VacuStar W into
operation once a month for 15 minutes. The VacuStar W must be
prelubricated prior to start-up (refer to chapter lubricating oil
inspection, chapter 6.4.)
Содержание VacuStar W1300
Страница 38: ......