6.3 Switching off
To switch off the VacuStar W, proceed as follows:
Switch off drive for the VacuStar W
Close shut-off valves (if available)
6.4 Inspections to be performed
Lubricating oil inspection
Only lubricating oils pursuant to the lubricants specifications on
page 17 are approved for the VacuStar W series.
Ölstand am Schauglas kontrollieren und falls erforderlich bis ca.
3 cm unter Gewinde des Einfüllverschlusses mit Öl füllen. The oil
level may not drop below the bottom mark on the oil inspection
glass.
Manual prelubrication of the VacuStar W is always necessary:
in case of initial operation
in case of recommissioning after a standstill of more than 4
weeks
after sucking over of foreign matter
after repair work on the VacuStar W
Procedure to be followed for manual prelubrication:
Remove the crank handle from the retaining bracket and push it
through the oil filler neck onto the oil pump shaft. Push the
crank handle down until the drive dog engages and now
prelubricate for approximately 40 full turns.
Afterwards, clip crank handle back into the retaining bracket
and screw locking screw back on again.
Fig. 2: Oil pump
1
Crank handle
2
Oil filler neck screw
3
Lubricating oil pump
4
Lubricating oil drain screw
The oil reservoir must be filled up before every suction process!