CVE TouchOne CFS-1700 Скачать руководство пользователя страница 4

6

7

1.4 Technical Specification

Item

Technical parameters

Fingerprint sensor

The 4

th

Generation CMOS Optical Sensor

Sensor resolution(sensing size)

500 dpi (16 x 19mm)

Enrollment time

< 1 second

Verification time

< 1 second

False Rejection Rate (FRR)

1/30 ~ 1/100

False Acceptance Rate (FAR)

1/100,000 ~ 1/1,000,000

Fingerprint Scanning

twice to get on fingerprint template

User Capacity

up to 99 fingerprints (1:N), 1,000 fingerprints (1:1) 

Initiation sensor

Infrared Sensor applied

Lock Type

UL Grade 1 latch(Standard), Mortise (Option)

Supply Voltage

DC 12V 

Power

1.5V AA x 8 Alkaline battery

Battery life

Approx. 12 months (20 times/day)

LED Display

ID Number, or program or error codes 

Emergency Power Source

Terminal for 9V square battery

Emergency Override Key

Mechanical Cylinder Key 

LED Display

ID Number indicator  

Audible/Visual Guidance

Voice/Silence, LED and Buzzer 

Audit Trail

Entry log data downloadable up to 1,000
events (Option)

Thickness of the door

38mm ~ 60mm

Material

Body         : Zinc alloy die-casting
Battery Cover : AL alloy fie-casting

Dimension

Front Body : 80(w) x 290(h) x 39(d)mm
Back Body : 80(w) x 290(h) x 39(d)mm

Weight (Net)

4.2 Kg

Operating Environment

- Temperature  :       -20

~ +70

- Humidity      :        45% RH-80% RH

Safety Certification

FCC, CE

2. Programming

The function button used for programming is hidden by the battery cover on the
back body. This means that only people authorised to be on the inside and with
knowledge of the lock programming will be able to add/delete/change data and
settings. The door will need to be open when programming, in order to give access
to the front and back of the lock.

Helpful Hints for Programming

1.User Access Codes (PIN Code) :

- Default User Access Code under ID number at “01” : “0000”

- All User Access Codes consist of 4 to 12 digits

2. Management Levels and fingers identified by ID numbers that

correspond to the stored fingerprints :

- Master Finger : 1 fingerprint at ID number “00” assigned automatically 

- Sub master fingers : 9 fingerprints at ID numbers “01” ~ “09”

- User fingers : 990 fingerprints at ID numbers “10” ~ “999” 

Master finger or sub-master fingers are required to be verified for all
programming procedure in “Master Finger Mode” only

3.Information to be recorded for future use

-ID numbers and personal details of fingerprint enrollment

-ID numbers and User Access Codes

4. Fingerprints Enrollment

- Several finger enrolment (one finger from each hand) are recommended for

master and sub-master fingerprints

- Pointer fingers are recommended to use when enrolling fingerprints

5. Definition of LED Display

- F0 : Initiate Programing

- no : Lock is waiting for the entry of function code

- i d : Lock is waiting for the entry of ID number 

- P0 : Lock is waiting for the entry of User Access Code (PIN Code)

6. Indication of Beep Sounds

- Double beep sound and a red light : Unsuccessful programming or Verification

- Triple beep sound and a green light : Successful programming or Verification

- Alarm sound : Low battery needs to replace batteries with new ones

Содержание TouchOne CFS-1700

Страница 1: ...ngly recommended that you keep this manual for future reference The design and specification of this product are subject to change without prior notice for product development improvement purposes CRE...

Страница 2: ...Should you experience any problem or need assistance please call our Tech Support line at 201 905 9205 or email support cveamericas com 1 Introduction 1 1 ProductConcepts Designed for User convenience...

Страница 3: ...ensor LED indicator Green Access granted Red Access denied Emergency Key Cover Fire rated handle Battery Cover Front Body Back Body No 1 2 3 4 5 6 7 8 Description Outer Body Inner Body Battery Cover R...

Страница 4: ...on the inside and with knowledge of the lock programming will be able to add delete change data and settings The door will need to be open when programming in order to give access to the front and ba...

Страница 5: ...e 3 Pointer fingers are recommended to use when enrolling fingerprint They are the easiest and most convenient fingers to use in programming and verification process 2 1 1 How to enroll master finger...

Страница 6: ...ck is waiting for entry of function codes for example 01 for sub master or user enrolment for further programming refer to 3 1 for programming code table You can exit from programming mode by pulling...

Страница 7: ...erprint please press the user ID and If you press only the ID shared automatically so the enrollment can be settied at sub master finger 12 13 2 1 3Howtoenrolluserfingers IDNumber10through999 The ID n...

Страница 8: ...00 is protected from deleting by this mode for the safety reason To stop deleting individual fingerprint please pull down the sliding cover in front body 15 2 2 2 How to delete all Fingerprints from...

Страница 9: ...lling and changing PIN Code press 04 and button and then repeat Step 5 through Step 7 16 17 2 3UserAccessCode PINCode 2 3 1 How to enroll User Access Code PIN Code Each lock comes with the factory def...

Страница 10: ...ound and green light indicate the successful deletion To continue deleting a User Access Code press 05 and button and then repeat Step 5 2 3 3 How to delete all User Access Codes PIN Codes Step 1 Open...

Страница 11: ...ody of the lock The fingerprint sensor will then turn on with a red light Step 5 Enter 0 and then press button Voice prompt saying Manual closing mode will be heard to indicate success of Temporary Un...

Страница 12: ...s certain enrolled people to be granted or denied access for temporary periods on a regular or irregular basis Note The total number of fingerprints that can be temporarily removed from the lock is li...

Страница 13: ...5 2 Reinstate a single removed fingerprint to the lock Step 1 Open the battery cover and press the F button in the back body of the lock Step 2 Pull up the sliding cover in the front body of the lock...

Страница 14: ...indication of the results of programming or operation This mode recommended to be used in the facilities requiring silence such as library at night etc Note Voice guidance of warning such as Batterie...

Страница 15: ...installed in strong direct sunlight Note Permanent use of the automatic Fingerprint Sensor On mode may slightly reduce battery life 2 7 1 How to set automatic Fingerprint Sensor On mode Step 1 Open t...

Страница 16: ...then press button Voice prompt saying Function installed will be heard to indicate success of Manual Sensor On mode setting 2 8TimeSettingmode This is the mode to set the month date time which is req...

Страница 17: ...master or sub master finger to be verified for programming Therefore anyone who has knowledge on the programming of this lock can enroll delete fingerprints and program change settings Note You are h...

Страница 18: ...print by ID 03 MF 03 and ID and Delete all fingerprints 00 999 using P W 01 Master Finger 04 01 05 Individual MF 04 and ID and Enter PIN Code Do PIN and twice 4 12 digits PIN code and 0000 factory def...

Страница 19: ...The red sensor light indicates the finger is being scanned and compared to the stored template This should take less than 1 second The motor driving sound of the latch or mortise unlocking and the tri...

Страница 20: ...ipe gently with a clean soft dry cloth to remove any dirt residues stains or moisture A low battery warning alarm will sound when the batteries run down to less than 30 of full power You should then r...

Страница 21: ...osition position by someone on the If 9V battery does not work inside Red indicator flashes with Invalid or deleted fingerprint Place an enrolled and double beep sound and Fingerprint covered obscured...

Страница 22: ...ID No Date Person Finger Record each ID number its date of enrollment and a fingerprint description for future reference ID No Date Person Finger ID No Date Person Finger Record each ID number its dat...

Отзывы: