34
35
Step 3
: Place the master finger or the sub-master finger on the glass of the
sensor to verify (LED displays “FO-no”)
Step 4
: Press “13” and “#” button (LED displays “id”)
Step 5
: Enter “1” and then press “#” button. Voice prompt saying “Function
installed” will be heard to indicate success of Administrator mode
setting.
ID number of administrator or user finger mode setting
0 : User finger mode
1 : Administrator mode (Factory Default Mode)
In user finger mode (ID “0”), there is no step for master (or sub-master)
finger verification before the programming process.
Note
: 1. In user finger mode, master fingerprint or sub-master fingerprints will
be changed to just user fingerprints. When you change the mode
back to “Administrator” mode, Master (sub-master) fingerprints will
2. Any fingerprint enrolled in ID number at “01” ~ “10” in “User finger”
mode will be converted to sub-master fingers automatically
2.10 Programming Code Summary Table
Programming process comparison between Administrator and User Finger
Mode (in enrolment of user fingerprint at ID number “24”)
Administrator mode
- “F” button -> Master finger -> “01”->“#”-> “24” -> “#” -> finger placement
User Finger Mode
- “F” button ->“01” ->“#” -> “24” -> “#” -> finger placement
Code
ID
Keystroke
Function
(“no”)
(“id”)
01
01 ~09
Sub-masters
“MF” “01”and “#”- “ID”and “#”
Fingerprint enrolment (Sub-masters)
10~ 999 Users
“MF” “01”and “#”- “ID”and “#”
Fingerprint enrolment (Users)
02
01~999
Individual
“MF” “02”and “#”- “ID”and “#”
Delete single fingerprint by ID
03
“MF” “03”and “#”- “ID”and “#”
Delete all fingerprints (“00~999”) using
-P/W(01)-”#”
Master Finger
04
01~05
Individual
“MF” “04”and “#”- “ID”and “#”
Enter PIN Code (Do PIN and # twice)
(4~12 digits)
-PIN code” and “#°”
“0000” factory default PIN code at “01”
05
01~05
Individual
“MF” “05”and “#”- “ID”and “#”
Delete PIN Code
06
“MF” “06”and “#”
Delete all PIN Codes (“01” ~ “05”)
PIN Code (0000) at “01” will be reinstated
07
0
“MF” “07”and “#”- “0”and “#”
Temporary Unlock Mode
1
Factory Set
“MF” “07”and “#”- “1”and “#”
Automatic Locking Mode
08
01~999
“MF” “08”and “#” - ID- “#”
Temporary removal of a fingerprint
(Max. 20 fingerprints) Only Users
09 01-999
“MF” “09”and “#” - ID- “#”
Reinstate temporarily removed fingerprints
10
1
Voice Mode
“MF” “10”and “#” - “1”and “#”
11 voice guidance messages
2
Buzzer Mode
“MF” “10”and “#” - “2”and “#”
Low battery warning(voice prompt)is effect
0
Silence Mode “MF” “10”and “#” - “0”and “#”
Low battery warning(voice prompt)is effect
11
0
Factory Set
“MF” “11”and “#” - “0”and “#”
Automatic Sensor on Mode
1
“MF” “11”and “#” - “1”and “#”
Manual Sensor on Mode
12
Time setting
“MF” “12”and “#” - “Time
Year,month,day,date,time,minute,second
(13 digits)”and “#”
Date : Sun(0), Mon(1)
Sat(6)
EX) 06,07,08,6,14,25,36 (13 digits)
For July 8, 2006 (sat) 2:25:36 PM
13
0
“MF” “13”and “#” - “0”and “#”
User Finger Mode
1
Factory Set
“MF” “13”and “#” - “1”and “#”
Administrator (Master Finger) Mode
Key Strokes are based on Administrator mode where master finger (or sub-
master finger) should be verified for programming
ID number marked with asterisk (
) means standard mode pre-set in the factory
“no” and “id” are the indication displayed on LED in the front body.
- “no” indicates lock is waiting for the entry of code number
- “id” indicates lock is waiting for the entry of ID number