Curtiss-Wright | PG Drives Technology
R-net Omni2 Technical Manual | Chapter 3 – Programming | 65
SK81935-01
2.9.4 MENU NAVIGATION
This parameter allows the user to invert the navigation direction of the User Menu with their SID. This parameter is not
adjustable with 3-Axis-Type SIDs.
The programmable options are Normal and Invert.
If set to Normal, operations of the SID in the forwards direction will navigate the menu upwards.
If set to Invert, operations of the SID in the forwards direction will navigate the menu downwards.
2.9.5 MENU SCAN RATE
This sets the scanning rate for the User Menu, Lights Menu and Settings Menu. If User Control is set to Sequence, the scan
rate will only be applicable in the Lights and Settings menus.
The programmable range is between 0s and 10s in steps of 0.25s. (If set to 0s no scanning is possible within menus).
2.9.6 AUTO-REPEAT
This sets whether there is an auto-repeat function on the direction commands for various SIDs. Auto-repeat means that
successive commands will be applied if the switch is continuously operated, which is useful when navigating the User Menu.
This is not desirable usually, in head control applications.
There are two programmable options, On and Off.
If set to On, there will be an auto-repeat function.
If set to Off, there will be no auto-repeat function.
2.9.7 FWD/REV AUTO TOGGLE
This sets the method of changing direction with 3-Axis SIDs. This parameter has no effect with any other type of SID, i.e. it is
intended for use primarily in head control applications.
There are three programmable options, On, Off and Timed.
If set to On, then an operation of the SID’s Fwd/Rev command can be used to change the selected drive direction. This is
achieved by operating and releasing the Fwd/Rev command within the period defined by Auto Toggle Time. This will change
the previously selected drive direction. To drive in the newly-selected direction then the Fwd/Rev command must be
operated again within the programmed value of Auto Toggle Time. If the programmed value of Auto Toggle Time passes
without a Fwd/Rev command, then the selected direction will revert to the original setting.
If set to Off, then a short operation of the User Switch selects a new drive direction and double-clicks of that switch will enter
the User Menu or sequence through the other available functions.
If set to Timed, the selected drive direction will automatically toggle when in standby, at the rate set by Auto Toggle Time.
Содержание R-NET OMNI2
Страница 1: ...PG DRIVES TECHNOLOGY R NET OMNI2 TECHNICAL MANUAL SK81935 01 ...
Страница 8: ...Curtiss Wright PG Drives Technology SK81935 01 8 R net Omni2 Technical Manual ...
Страница 28: ...Curtiss Wright PG Drives Technology SK81935 01 28 R net Omni2 Technical Manual Chapter 1 Installation ...
Страница 52: ...Curtiss Wright PG Drives Technology SK81935 01 52 R net Omni2 Technical Manual Chapter 2 Operation ...
Страница 74: ...Curtiss Wright PG Drives Technology SK81935 01 74 R net Omni2 Technical Manual Chapter 3 Programming ...
Страница 102: ...Curtiss Wright PG Drives Technology SK81935 01 102 R net Omni2 Technical Manual Chapter 5 Infrared Control ...
Страница 118: ...Curtiss Wright PG Drives Technology SK81935 01 118 R net Omni2 Technical Manual Chapter 6 Bluetooth Set Up Operation ...
Страница 147: ...Curtiss Wright PG Drives Technology R net Omni2 Technical Manual Chapter 9 Specifications 147 SK81935 01 ...
Страница 152: ...Curtiss Wright PG Drives Technology SK81935 01 152 R net Omni2 Technical Manual Chapter 9 Specifications ...