5
EXPERT WW rev.12
EXPERT WW
1.3. Controller’s Overview
The EXPERT WW is an electronic device
used for environmental control in livestock
buildings. It combines sidewall and tunnel
ventilation into one powerful system.
20 built-in relays &
32 optional relays to control:
4 heating stages;
12 fan stages;
2 tunnel doors;
2 natural ventilation curtains;
2 vent doors (inlets);
2 clock outputs;
1 misting output;
1 cool cell output;
4 feeders;
1 backup relay;
1 built-in 0-10V output to control an inlet or
variable-speed fans;
1 built-in 0-10V output to control lighting
equipment.
INPUTS:
8 inside temperature sensors;
2 outside temperature sensors;
1 inside humidity sensor;
1 outside humidity sensor;
1 static pressure probe;
9 water meters.
Refer to the end of this manual to con-
nect the sensors and loads.
1. INTRODUCTION
1.1. Precautions
WARNING: Read and save these in-
structions!
Safety may be jeopardized if the equipment is
used in a manner not specified by the manu-
facturer. Carefully read and keep the following
instructions for future reference.
We strongly recommend installing supplemen-
tary natural ventilation as well as a backup
thermostat on at least one cooling stage.
Although fuses at the input and outputs of
the controller protect its circuits in case of
an overload or over-voltage, we recommend
installing an additional protection device on
the controller’s supply circuit.
The room temperature where the controller
is located must always remain between 32°F
and 104°F (0°C to 40°C). Indoor use only!
To avoid exposing the controller to harmful
gases or excessive humidity, it is preferable
to install it in a corridor.
If the equipment is used in a manner not
specified by the manufacturer, the protec-
tion provided by the equipment may be
impaired.
Do not spray water on the controller! In
order to clean the control, wipe it with a
damp cloth.
Before servicing or cleaning unit, switch
power off at service panel and lock the
switch disconnecting means to prevent
power from being switched accidentally.
When the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
1.2. Symbols of the Manual
Warning. Read the following text
carefully; it contains important
information which, if ignored, may
cause the controller to operate
improperly.
High Voltage. Hazard of electrical
shock. Read the message and follow
the instructions carefully.
Pay attention. The following text
contains very useful information.
Press on the proper menu selector.
Press the “Main Menu” push-button.
Both direct and alternating current
(AC/DC).
Direct current (DC).
Alternating current (AC).
Earth Ground Terminal
Primarily used for functional earth
terminals which are generally asso-
ciated with test and measurement
circuits. These terminals are not
for safety earthing purposes but
provide an earth reference point.
For Customer Use:
Enter below the serial
number located on the side of the alarm
system and keep this information for future
reference.
Model: EXPERT WW
Serial number:
Date installed: