EXPERT WW rev.12
EXPERT WW
1. Select:
Main menu
Start/Stop*
Misting **
Misting Settings
Use to navigate
On Temperature
85.0 °F
Off Temperature
83.0 °F
Minimum On Time
15 sec
Minimum Off Time
900 sec
Maximum Temperature
87.0 °F
Maximum On Time
180 sec
Maximum Off Time
900 sec
Start at
6:00A h:m
Stop at
9:00P h:m
* A password may be required to access this menu.
** This menu is accessible if the misting output is
enabled in the Installation Setup (section 4.5).
2. Set the following parameters:
On temperature —
Select the temperature at
which the misting output starts.
Off temperature —
Select the temperature
below which the misting output stops.
Minimum On & Off times —
Set the on & off
times of the minimum misting timer.
Maximum Temperature —
Set the tempera-
ture at which the maximum misting timer if
used.
Maximum On & Off times —
Set the on and
the off times of the maximum misting timer.
Start & stop at —
Specify the period of time
over which the output can run.
7. HEATING
The controller can control up to 8 indepen-
dent heating outputs. Each heating output
operates according to its start and stop
temperature. Refer to section 4.5 to enable
heating outputs.
Reference Temperature:
The start/stop tem-
peratures of the heating outputs are related
to the set point. This means that they are
automatically adjusted when the set point
changes.
1. Select:
Main menu
Start/Stop*
Heaters
Heaters Start / Stop
Use to navigate
Heater 2
Lo fire
On 71.0 °F
Off 73.0 °F
Hi fire
On 70.0
°F
Off 73.0 °F
Heater 1
Lo fire
On 73.0 °F
Off 75.0 °F
Hi fire
On 72.0
°F
Off 75.0 °F
* A password may be required to access this menu.
Heater Stage
Heating
Output
Heater 1
Hi Fire ON
Heater 1
Lo Fire ON
Heater 1
Hi Fire OFF
Heater 1
Lo Fire OFF
Heater 1
Hi Fire
Stop T°
Heater 1
Hi Fire
Start T°
Heater 1
Lo Fire
Start T°
Heater 1
Lo Fire
Stop T°
T° of
heater’s
probes
Heaters 1-4:
The controller has 4 basic heat-
ing outputs.
Heaters’ Hi Fire:
In addition to its 4 basic
heating outputs, the controller can simulate
additional heating outputs with the Hi Fire op-
tion. When this option is used, the controller
doubles the number of heating outputs in use.
Each simulated heating output (Hi Fire Step)
operates as a regular heating output, with its
own start/stop temperatures, relay selection
and probe selection. Refer to section 4.5 to
activate the heaters’ Hi fire option.
2. Set the following parameters:
On temperature —
Set the temperature below
which each heating stage starts. If the Hi/Lo
fire option is used, set this temperature sepa-
rately for both steps of the heating stage.
Off temperature —
Set the temperature at
which each heating stage stops. Note that
the
“Off Temperature”
of an heating stage must
be at least 0.5°F (0.3°C) higher that its
“On
Temperature”
. If the Hi/Lo fire option is used,
set this temperature separately for both steps
of the heating stage.