40
EXPERT WW rev.12
EXPERT WW
12. MONITORING FUNC-
TIONS
12.1. Current Conditions
The current condition menu gives a quick
overview of the actual conditions in the
barn.
1. Select:
Main menu
2. The current conditions (inputs and output)
are shown on screen. Use the arrow keys to
scroll the display.
Installation
Set Points
Min. Vent.
Vent/Inlet
History
Age/Mortal
Clean Mode
Start/Stop
Monitoring
Program
Selection
Setup
Time/Date
Use to navigate
Ambient Temperature
72.3 °F
Current Stage
2
Current Probe
Set 1
Set Point
70.0 °F
Inside Humidity
Low %
Outside Humidity
Low %
Static Pressure
.000 “WC
Outside T°
High °F
Heating Stages
xx
Clock Output
xx
Vent/Inlet 1 Position
0 %
Vent/Inlet 2 Position
0 %
Running Prog:
Program 1
Temperature Probe 1
72.3 °F
Temperature Probe 2
72.4 °F
Temperature Probe 3
72.3 °F
Temperature Probe 4
72.1 °F
Yesterday Water 1
0 Gal
Yesterday Water 2
0 Gal
Yesterday Water 3
0 Gal
12.3. History Menus
History menus give a daily record of probe
readings and of the animal count. These
pieces of information are logged into history
menus at midnight. Refer to section 12.2 to
consult run time histories (for heaters, water
consumption and feeders).
1. Select:
Main menu
History
Select the desired type of history:
Ambient temperature —
This menu contains
the daily minimum and maximum readings of
the room temperature of the past 60 days.
Probe temperature —
This menu contains the
daily minimum and maximum temperature
readings of each temperature probe for the
past 10 days.
Outside temperature —
This menu contains
the daily minimum and maximum readings of
outside temperature probes for the past 75
days. *
This parameter is accessible if an outside
temperature sensor is enabled (section 4.7.1).
Inside relative humidity (RH) —
This menu
contains the daily minimum and maximum
inside humidity readings of the past 75 days.
* This parameter is accessible if the inside humidity
sensors is enabled (sec. 4.7.1).
Outside relative humidity (RH) —
This menu
contains the daily minimum and maximum
outside humidity readings of the past 75 days.
*
This parameter is accessible if the outside humidity
sensors is enabled (sec. 4.7.1).
Static Pressure —
This menu contains the
daily minimum and maximum static pressure
readings of the past 75 days. *
This parameter
is accessible if a static pressure sensor is enabled
(sec. 4.7.1).
Mortality / Culled / Marketed —
These menus
contains the daily count of mortalities, culled,
and of marketed animals of the past 75 days.
*This parameter is accessible if age-based functions
are enabled (section 4.5).
Water Consumption —
This menu contains
the daily water consumption measured by
each water meter for the past 75 days. *
This
parameter is accessible if at least one water meter
is enabled in section 4.7.1.
12.2. Run Time Histories
Monitoring menus contain the daily run time
of the following outputs: water meter, feed-
ers & heaters. The controller keeps these
daily run times in memory for 75 days and
logs these values into monitoring menus at
midnight.
1. Select:
Main menu
Monitoring
Select the desired monitoring menu:
- Feeders
- Heaters
Total
0 min
Today
0 min
Jan 02 200X
0 min
Jan 01 200X
0 min
Heater Run Time 75 days
Use to navigate
Resetting the run time of a feeder
To reset the run time of a feeder, select the
following menus then follow the prompts
on screen.
1. Select:
Main menu
Monitoring
Feeders
Reset Run Time