REMOTE CONTROL ONLY OPTION
AN-2A
Rev A
DIP-SWITCH FRONT PANEL DOWN LOAD PROCEDURES
To down load the software via the DIP switch, follow the procedure as outlined below.
1.
Turn the power off to the unit.
2.
Set DIP Switch 1 on S1 to ON.
3.
Set address on S2 to 3 for the Control Program, 1 for DSP1, or 2 for DSP2.
a. Address 3; Set DIP Switches 7 & 8 of S2 to ON, all other DIP Switches on S2 set to OFF.
b. Address 2; Set DIP Switches 7 of S2 to ON, all other DIP Switches on S2 set to OFF.
c. Address 1, Set DIP Switches 8 of S2 to On, all other DIP Switches on S2 set to OFF.
4.
Set DIP Switch 2 to the one of the following:
a. For RS-232, set to OFF
b. For RS-422, set to ON
c. For IEEE 488, DIP Switch settings have no effect. (e.g. DIP Switches can be set to ON or OFF)
5.
Set DIP Switch 3 on S1 to OFF.
6.
Set the Baud Rate using DIP Switches 5 - 8 on S1 as follows:
BAUD
DIP SWITCH SETTING
38,400
5 & 7 set to ON
6 & 8 set to OFF
19,200
5 & 8 set to ON
6 & 7 set to OFF
9,600
5 set to ON
6 , 7, & 8 set to OFF
2,400
6 & 7 set to ON
5 & 8 set to OFF
1,200
6 & 8 set to ON
5 & 7 set to OFF
7.
Using RCOMM with flow control off and the correct baud rate, select the upload file and depress the enter
key.
8.
Turn the power on to the unit.
9.
Repeat steps 1 - 8 for each program to upload.
10. Reset the address switch to 0 or the desired address
11. Turn DIP Switch 1 on S1 to OFF
12. Power on the unit and verify download using ID? and IDD?