![Cubic Communications CDR-3250 Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/cubic-communications/cdr-3250/cdr-3250_technical-manual_2695428104.webp)
CDR-3250/80 TECHNICAL MANUAL
Issue 2.2
5-1
WARNING
CAUTION
CAUTION
WARNING
CHAPTER 5
MAINTENANCE INSTRUCTIONS
Section I. PREVENTIVE MAINTENANCE
5-1 INTRODUCTION.
This chapter contains both preventive and corrective
operational level maintenance instructions. The informa-
tion includes cleaning and lubrication, inspection, perfor-
mance verification, troubleshooting, and subassembly
removal and replacement.
5-2 CLEANING AND LUBRICATION.
Clean the external surfaces and front panel of the unit every
2 weeks using a vacuum cleaner or small soft brush to
remove any dirt or dust. Do not use any cleaning agents.
There are no lubrication requirements.
5-3 INSPECTION.
If the unit is faulty or suspected to be faulty perform a
visual inspection as follows:
5-3.1
External Inspection.
1. Check front panel for physical damage.
2. Check external case for physical damage.
3. Check rear panel for physical damage.
4. Check rear panel connectors for corrosion and
loose connectors.
5. Check rear panel cables for frayed or broken wires.
5-3.2
Internal Inspection.
With the front panel power/volume knob
set OFF and the power cord plugged into
the power source, high voltage shock
danger is present internally at the rear panel
POWER receptacle/RFI filter, optional AC
Line Filter board, rear panel circuit breaker,
and the front panel power switch
connections.
When working on the receiver with
covers removed and power applied, do
not allow tools or metal objects to come
in contact with receiver components.
Equipment damage may occur.
Unit contains parts and assemblies
sensitive to damage by electrostatic
discharge (ESD). Use ESD precautionary
procedures when touching removing or
inserting parts.
1. Turn the unit off, and remove the power cord from
the power source.
2. Remove the top and bottom covers of the unit as
follows:
CDR-3250: Using a no. 2 Phillips screwdriver,
push down and turn all captive fasteners on the
covers 1/4 turn counter-clockwise, and remove the
covers.
CDR-3280: Using a no. 1 Phillips screwdriver,
remove 4 screws from both sides of chassis for
each cover, and then remove the covers.
3. Check for loose modules and circuit boards.
4. Check for loose connectors, corrosion, or burn
marks.
5. Check for frayed or broken wires.
5-4 PERFORMANCE VERIFICATION.
With the front panel power/volume knob
set OFF and the power cord plugged into
the power source, high voltage shock
danger is present internally at the rear panel
POWER receptacle/RFI filter, the optional
AC Line Filter board, rear panel circuit
breaker, and the front panel power switch
connections.
Courtesy of http://BlackRadios.terryo.org