36
CTC EcoLogic S
9.1
Information messages
Information messages are displayed when appropriate and are intended to
inform users about various operational situations.
[I013] Start delay
The compressor is not allowed to start too quickly when it has stopped. The
delay is usually at least 10 minutes.
[I003] Compressor blocked
The compressor is set to be shut down, e.g. before drilling or digging
has been carried out for the collector coils. The product comes with the
compressor switched off. This option is selected in the "Installer / Settings /
Heat Pump" menu.
[I030] Driver block undervoltage
The heat pump has stopped due to insufficient mains voltage. The product
will attempt to restart.
[I031] Driver block alarm
The heat pump has stopped due to driver failure; for example, voltage or
excessive temperature. The product will attempt to restart.
9.2
Alarm messages
If a fault occurs with e.g. a sensor, an alarm is triggered. A message appears
on the display with information about the fault. In the event of an alarm, the
LEDs on the display and room sensor also flash.
You reset the alarm by pressing the “Reset alarm” button on the display.
If several alarms are triggered, they are displayed one after the other. A
persisting fault must first be rectified before it can be reset. Some alarms are
reset automatically if the fault ceases.
[E055] Wrong phase order