25
CTC EcoLogic S
3.5.2
Alarm log
In the alarm log, up to 500 alarms can be displayed.
An alarm which reoccurs within an hour is ignored so as
not to fill up the log.
Click an alarm row to see more information about an
alarm.
If it is a "sensor alarm", a sensor value will be displayed
at the bottom of the page from when the alarm was
triggered for further troubleshooting.
For alarms related to the heat pump, values can
be displayed from sensors for pressure (HT, LT),
temperature (OP) and current (I).
3.5.3
Alarm dumps
Export the alarms displayed in the alarm dump to a USB
drive. A dump can consist of one or more alarms as well
as a number of values before and after the alarm was
triggered.
3.5.4
Settings coded
This menu is intended to set the manufacturer’s
operational and alarm limits. A 4-digit code must be
specified to be able to amend these limits. However, you
can view options in most menus without having to use
a code.
3.5.5
Quick start compressor
The delay normally prevents compressor start earlier
than 10 mins after compressor stop. The delay is also
activated in the event of a power failure, or the first time
after production is started.
Menu: "Installer / Service/ Alarm Log".
Menu: "Installer / Service / Alarm Dumps".
Menu: "Installer / Service / Coded settings".
!
NB: Only an authorised service engineer is allowed to log in to the Factory settings
coded option. Severe operational problems and faults may occur affecting the
product if values are amended without authorisation. Note that in such cases the
warranty terms do not apply.