3.3.2
Settings Heat pump
Compressor
Blocked (Permitted/Blocked)
The heat pump is supplied with a blocked compressor.
"Permitted" means that the compressor is allowed to
start.
Stop at outdoor °C
-22 (-22...10)
This menu relates to settings for the outdoor
temperature at which the compressor is no longer
permitted to operate. The heat pump starts 2°C above
the set value.
Only applies to air-to-water heat pumps.
Charge pump %
50% (20...100)
The speed of the charge pump is set here.
Refer to the heat pump’s "Installation and Maintenance
Manual" for more information.
Cold temp limit
0 (0...-15)
Temperature limit for "winter power".
When the outdoor temperature is equal or lower (T2),
the compressor speed is adjusted up to speed R2.
Only applies to modulating air-to-water heat pumps.
Max rps
90* (50...120)
The maximum permissible speed of the compressor at
"winter temperature". Sets the compressor’s maximum
speed (R2) at outdoor temperature T2.
Only applies to modulating air-to-water heat pumps.
Warm temp limit
20 (0...20)
Temperature limit for "summer power". When the
outdoor temperature is equal or higher (T1), the
compressor speed is adjusted down to speed R1. The
heat pump starts and stops at the actual value and
setpoint value.
Only applies to modulating air/water heat pumps.
Max rps warm temp
50 (50...120)
The maximum permissible speed of the compressor
at "summer temperature". Sets the compressor’s
maximum speed (R1) at outdoor temperature T1.
Only applies to modulating air/water heat pumps.
Compressor stop at brine °C
-5 (-7...10)
Specify the brine temperature at which to stop the
compressor.
Only applies to liquid/water heat pumps.
Outdoor °C
The diagram shows that the compressor speed is controlled
according to the outside temperature.
When the outside temperature is below T2, the compressor
speed adjusts up to R1.
When the outside temperature exceeds T1, the compressor
speed adjusts down to R1.
These temperature and speed limits are set in the menus on
the left.
*The value may vary depending on the heat pump model.
Menu: "Installer / Settings / Heat Pump".