CTC EcoLogic S
5.
Electrical installation
The installation must be carried out in accordance with the applicable standards.
Installation and connections in CTC EcoLogic must be performed by a licenced
electrician. All wiring shall be installed according to applicable local requirements.
5.1
Power supply
Supply
24V DC
EcoLogic is powered by the heat pump via a supplied communication cable.
Power supply and communication are routed through a shared cable.
5.2
Communication between EcoLogic
and EcoAir/EcoPart
LiYCY (TP) is used as a communication cable. The cable is 4-core shielded
cable, where the communication cores are of twisted pair type. The display (A1)
is connected to the heat pump circuit board (A5) according to the wiring diagram
"Connecting control card EcoAir/EcoPart".
5.3
Outdoor sensor B15 (EcoPart)
Outdoor sensor (B15) connects to control card EcoPart on terminals U5 and
GND, refer to wiring diagram "Connecting control card EcoAir/EcoPart".
5.4
Thermostat control K26 / control
signal external 3-way valve
Thermostat control K26 and control signal from external 3-way valve (when
switching heating/DHW) connect to HP control card (A5) as follows:
EcoAir 400 / EcoPart 400 / EcoAir 500
Connection to terminal DI3 and GND (see wiring diagram “Connecting control
card EcoAir/EcoPart”.
EcoAir 600 / EcoPart 600
Connection to terminal DI1 and GND (see wiring diagram “Connecting control
card EcoAir/EcoPart”.