![CS-Lab SimDrive M4-H040K Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/cs-lab/simdrive-m4-h040k/simdrive-m4-h040k_user-manual_2692496038.webp)
In most of cases at this stage of the tuning the procedure is finished but for new machines or
machines that were not used for a long time probably you will have to tune current and position
controller once again when mechanics is livened up and run in.
In case an axis has a tendency to go into vibrations you can try to suppress them by increasing K
d
gain of velocity controller. If it didn’t help you can try to decrease the K
p
of position controller by
10% and K
p
and K
i
of velocity controller as well.
To keep the changes saved after power supply is off – press icon on a toolbar after you done the
changes or select “Save to flash” from “Configuration” menu.
Remember to approve the values you type n by pressing „Enter”.
It is worth to watch “Max following error” parameter during tuning in a parameter monitor window
( ). After we finish the tuning we can set max allowed following position error in a PID tuning
window approximately on a four-fold value of measured max following error so if “Max following
error = 23” in a parameter monitor window,
then we set „Max following error” parameter in a PID
tuning window – to 100.
38
simDrive™ - AC Servo Drive User Guide
Содержание SimDrive M4-H040K
Страница 1: ...Applies to hardware version v1 Applies to firmware version v2 00 Rev 1 0 copyright 2014 CS Lab s c...
Страница 9: ...2 1 Brushless motors AC BLDC simDrive AC Servo Drive USER GUIDE 9...
Страница 10: ...2 2 Brushed motors DC 10 simDrive AC Servo Drive User Guide...
Страница 17: ...4 1 4 Digital inputs IN0 IN5 4 1 5 Digital outputs OUT0 OUT2 simDrive AC Servo Drive USER GUIDE 17...