5.3
„Parameters Monitor” window – real-time parameters preview
During drive configuration it's very useful to have the possibility to watch the parameters and
information about them up-to-date.
We call the preview window by clicking the icon on the toolbar or by selecting
„Tools
Parameters Monitor” from the menu.
On the left side of the window there is a list with the parameters. On the right upper side there is a
real-time data chart of chosen parameter. Under the chart there are options related to it:
•
Refresh frequency – the chart refresh frequency
•
Auto scale – automatic / manual scale of the chart Y axis
•
Max/Min – min/max values settings for Y axis if manual scale of Y axis is enabled.
Under the "chart control" group there are current digital inputs and outputs of a drive states
displayed along with functions assigned to them.
In the bottom part there is current position rate (user's units). It can be an angle, inch or mm. You
only have to enter encoder pulses number per the chosen unit in „Steps per unit" area. So if an
encoder has 10000p/rev and the drive is driven by 20mm pitch ball screw and we want to have the
axis position displayed as mm: 10000[p/rev] / [20mm/rev] = 500[p/mm]. So we enter 500 into the
"Steps per unit" area.
26
simDrive™ - AC Servo Drive User Guide
Содержание SimDrive M4-H040K
Страница 1: ...Applies to hardware version v1 Applies to firmware version v2 00 Rev 1 0 copyright 2014 CS Lab s c...
Страница 9: ...2 1 Brushless motors AC BLDC simDrive AC Servo Drive USER GUIDE 9...
Страница 10: ...2 2 Brushed motors DC 10 simDrive AC Servo Drive User Guide...
Страница 17: ...4 1 4 Digital inputs IN0 IN5 4 1 5 Digital outputs OUT0 OUT2 simDrive AC Servo Drive USER GUIDE 17...