Preset and factory reset
Note:
Care should be taken when storing presets that the desired configuration is not changed by any external
input prior to saving.
Saving and recalling presets
The current board settings can be saved in one of 16 locations to be recalled as desired. This
allows the user to store and recall up to 16 different configurations for later use.
To save the current settings, select the preset location and press enter. This will write the
current settings into this location.
Note:
If the selected location contains previously saved setting information it will be over-
written by the new setting data.
When pasting a board setup from Statesman, GPI enable will be set to disabled.
To recall previously stored setting information, again choose the selected location and press
enter to recall the stored configuration. The recalling of previously stored presets can also be
implemented externally via the GPI port. To sanction this facility, enable the GPI controls
preset recall box.
Factory reset
The user has the choice of performing a total factory reset or a partial reset. Factory Reset will
return all parameters to their factory default values and erase all user-stored configuration
presets. Selecting the Defaults option will perform the same reset to factory defaults values but
will leave any user-stored configurations unaffected.
Note:
Factory reset will erase all user-stored presets
Parameter
Default value
Mode
Synchroniser
Output Freeze
Off
Video input select
BNC
On loss of input show
Last Frame
Video delay controls
0
Output Audio Groups
Enabled
VANC Blank
Un-blanked
Tracking speed
0.05%
AES Setup
Terminated and Balanced inputs
Lock to ATC input
Free running
Invert output sequence
Normal
De-embedded Input Audio
Mono, Invert un-selected, Resample selected
AES Input Audio
Mono, Invert un-selected, Resample selected
Audio delay
Frame, User and TAD delays selected
Dolby E delay
Alignment selected
User delay
0
Embedder output routing
Group 1 to group 1…..Group 4 to group 4