Crystal Vision
Card edge operation
SYNNER-E 3G User Manual R1.2
39
10/09/2012
GPI Alarms menu
The GPO6 output is reserved for alarm indication and may have assigned any of the 38 video
and audio alarms.
Any number of alarms may be assigned to the GPI output; video missing and input groups
missing will assert an alarm immediately whereas the silence alarms can be assigned a delay
timer to delay the time after which an alarm is asserted. This ability is especially useful to
prevent false alarming during quiet periods in the audio.
Where more than one alarm is flagged and an alarm condition is asserted, use the various
status indicators to determine the exact cause.
Visual indication of GPO6 status is provided on the board edge.
See Section 2.3 for further discussion of GPIs and pinout details.
Menu
Comment
Silence delay
Rotate the SCROLL/ADJ. control to show the silence delay control.
Press ENTER and rotate SCROLL/ADJ. to vary.
0-128 seconds.
Input video
present
Rotate the SCROLL/ADJ. control to show the video missing alarm.
Press ENTER and rotate SCROLL/ADJ. to select.
On, Off.
External
reference missing
Rotate the SCROLL/ADJ. control to show the reference missing
alarms.
Press ENTER and rotate SCROLL/ADJ. to select.
On, Off.
Input audio
group 1 missing
Rotate the SCROLL/ADJ. control to show the input audio groups
missing alarms.
Group 1, Group 2, Group 3, Group 4.
Press ENTER and rotate SCROLL/ADJ. to select.
On, Off.
Input audio
group 4 missing
De-embedder
Grp1 Ch1-2 silent
Rotate the SCROLL/ADJ. control to show the de-embedder channel
silent alarms.
Group 1 channel 1-2 to Group 4 channel 3-4.
Press ENTER and rotate SCROLL/ADJ. to select.
On, Off.
De-embedder
Grp4 Ch3-4 silent
AES1 input silent
Rotate the SCROLL/ADJ. control to show the AES channel silent
alarms.
AES1 to AES8.
Press ENTER and rotate SCROLL/ADJ. to select.
On, Off.
AES8 input silent