Crystal Vision
Rear modules
Rear module connections with RM73
The RM73 being a single height module will allow maximum packing density with the
maximum number of outputs available. This module features relay bypass protection,
automatically switching the main output to BG IN in the event of power failure.
RM73 rear module connector
Description
RM73
•
12 per Indigo 2 frame
•
Six per Indigo 1 frame
•
Two per Indigo DT
•
All frame slots can be used
BNC connections
BNC
I/O assignment
FG IN
3G/High Definition/Standard Definition serial digital input
KEY IN
3G/High Definition/Standard Definition serial digital input
SYNC IN
Analogue Black & Burst or tri-level syncs reference for video synchroniser
BG IN
3G/High Definition/Standard Definition serial digital input
MAIN OUT (SWITCHED)
3G/High Definition/Standard Definition serial digital output
AUX OUT
3G/High Definition/Standard Definition serial digital output
Safire 3 User Manual R1.3
10