P148E Report Zone Tampers to Dialer
Zones 1-4. (Default = All zones)
This option allows the programming of zone tampers to be sent via the dialer to a Monitoring Station.
P149E Zone Reports Area “B” Account
Zones 1-4. (Default = All zones)
When a zone is in both partitions A&B this address allows the option of specifying which account number a zone
alarm will report to. The default is that a common zone will report to area A account code (P332E) but if this option
is on for a common zone it will report to area B account code (P333E).
P150E Inactivity Timer Zones
Zones 1-4. (Default = None)
This option allows the programming of which zones will be monitored for inactivity. All zones programmed with
this feature ON will be monitored for activity for the period set below (P240E). The inactivity timer only works
during the disarmed state and is accumulative, which means that if a zone does not trip at least once during a
disarm period the inactivity timer is not reset for that zone and will continue with the balance of the time period left
when the panel is next disarmed. The timer for each zone is reset every time a zone unseals.
PROGRAMMING ZONE INACTIVITY TIMER
P240E Inactivity Timer
- 0-255 Hours.
Default =120 Hours
PROGRAMMING ENTRY DELAYS
P301E
Zone 1 Entry Delay Time -
0-9999 Seconds (Default = 20 Sec)
P302E
Zone 2 Entry Delay Time -
0-9999 Seconds (Default = 20 Sec)
P303E
Zone 3 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
P304E
Zone 4 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
PROGRAMMING EXIT DELAYS
P219E
Partition “A” Exit Delay Time -
0-255 Seconds (Default = 60 Sec)
P220E
Partition “B” Exit Delay Time -
0-255 Seconds (Default = 60 Sec)
PROGRAMMING TWO TRIGGER TIMER
P229E
Two Trigger Timer -
0-255 Seconds (Default = 60 Sec)
Inactivity Timer
120
Zone 1Entry De-
20
Area A Exit Delay
60
Two Trigger Timer
60