PROGRAMMING ZONE EOL OPTIONS
ZONE EOL INPUT (4 zones)
-
P130E - Default=1-4 OFF
P130E 1-8E
Zone EOL input
- This option is used to define the PW-4 as a 4 zone panel with or without
EOL (End of Line Resistors) . Options 1-4 relate to zones 1-4 respectively and decide whether
the zone input requires an end of line resistor or just a short or open circuit to seal the zone. If
the LED’s are
OFF
(Type 1 Drawing on Page 5 )then a short on the input is all that is needed
to seal the input. If the LED’s 1-4 are
ON
(Type 2 Drawing on Page 5 ) then the input requires
a 2k2 resistor to seal the zone. Options 5-8 relate to zone inputs 1-4 respectively and allow
each input to be configured (Type 3 drawing on page 5 ) without tamper monitoring or (Type
4 drawing on page 5 ) with tamper monitoring. To use the Type 3 mode for zones 1 you must
turn LED#1 Off and LED#5 On. To use Type 4 mode for zones 1 you must turn LED#1 On and
LED#5 On. The same applies to the other zone inputs. Refer to the table on Page 5 for more
details.
PROGRAMMING ZONE OPTIONS
PROGRAMMING ZONE OPTIONS
–
P129E
,
P131E-P150E
This block of addresses (P129E - P150E) are used to select the desired functions for Zones 1-4
P131E Partition “A” Zones
Zones 1-4. (Default = All 4 zones)
This option allows programming of which zones will be assigned to Partition A. If a zone is in Both A & B then it
becomes common to both Areas.
P132E Partition “B” Zones
Zones 1-4. (Default = No zones)
This option allows programming of which zones will be assigned to Partition B. If a zone is in Both A & B then it
becomes common to both Areas.
P133E Zone is NC or NO
Zones 1-4. (Default =Led Off, All Zones NC, Normally Closed)
By turning the LED on for zone 1 at this address, the panel is now looking for a Normally Open (NO) contact on
the zone (4K7).
P134E Radio Zone Input
Zones 1-4. (Default = No zones)
This option allows programming of which zones will be radio zones. If a zone is a radio zone, the panel ignores
the state of the hardwired input for that zone). If the zone input has been set to tamper monitoring , the tampers
are still active even if zones are set for Radio operation.
P135E Manually BYPASSED Zone
Zones 1-4. (Default = All 4 zones)
This option allows programming of which zones can be manually BYPASSED prior to Arming. If a zone has this
option turned off, then that zone cannot be BYPASSED manually). Zones are BYPASSED during the disarm state
and normal zones which are BYPASSED become re-included once the alarm has been set then unset. 24 hour
zones, however remain BYPASSED until manually re-included again. Every time the alarm is set or unset with
zones BYPASSED the keypad will respond with a long beep instead of the normal 3 short beeps to indicate that
excludes are present. When excluding zones, the READY\EXCL & PROGRAM LED’s are on to indicate that you
have entered BYPASS mode. After BYPASSING zones the READY\BYP led will flash when all zones are sealed
to indicate that zones are BYPASSED
P136E Auto-BYPASSED Zone
Zones 1-4. (Default = All 4 zones)
This option allows programming of which zones can be automatically BYPASSED at the end of the exit delay if
unsealed at that time. If a zone has this option turned off, then that zone will not auto-BYPASSED and will go into
alarm if not sealed.
P137E Handover Zone
Zones 1-4. (Default = ONLY ZONE 2 = ON)
This option allows programming of which zones will be handover zones. If a zone is a handover zone then it’s
- - - - - - - -
EOL & Doubling