Option 6
No audible keypad beep on zone inactivity timeout -
If a zone is set for inactivity monitoring (P150E)
and it does not unseal at least once during the timeout period (P240E) an alarm will be generated. An
inactivity timeout will cause the trouble LED on the keypad to flash and the zone led that failed will be on
solid. If this option is off then all keypad buzzers will also sound continuously to warn of the problem. If
this option is on, the buzzers will not sound on a zone inactivity alarm but the trouble LED will still flash.
Option 7
“CONTROL” function disables day zones( CHIME )
- This option will disable the day zone monitoring
when “Control” is on. It is used to stop day zone beeps from occurring at the keypad or operating an
output when not needed. To initiate the “Control” function the operator must press The “Control” button
followed by the “Program” button. When the “Control” function is On the Program LED will flash.
Option 8
Silent 24 Hour Alarms (No keypad Buzzer)
- If this option is on then any 24 hour alarms (P129,140 or
141E) will not cause the keypad buzzer to sound i.e. silent alarm.
DURESS DIGIT
This address (P230E) is used to program the duress digit. The duress digit is a number from 1-9 (“0” means the
duress function is disabled) .To create a duress alarm the duress digit must be entered before a valid user code (eg If
the code was “123” and the duress number was “4”, then entering a code of “4123” “Enter” would create a duress
alarm).
P230E Duress Digit -
Value 1-9 (Default = 0, Disabled)
SETTING REAL TIME CLOCK
The Real Time Clock is used to Time & Date stamp the events in the Event Buffer. Ensure this is set correctly at the
time of installation so that the events have the proper time and date associated with them. The clock is programmed
in 24 hour format (e.g. 00:00-23:59).
P401E Real Time Clock Hour/Minute -
Value 0-2359
P403E Real Time Clock Day of Week -
Value 1-7 (where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc)
P405E Real Time Clock Date -
Value 1-31
P406E Real Time Clock Month -
Value 1-12
P407E Real Time Clock Year -
Value 0-99
SETTING DAYLIGHT SAVING START/FINISH
The real time clock can have preset automatic adjustments for the start & finish of daylight saving if applicable. If a
value of “0” is entered at addresses P408 & P411 then no daylight saving adjustments will apply. Otherwise set up
the parameters for the country concerned and the adjustments will become automatic every year.
P408E Daylight Saving Start Sunday -
Value 0-5 - Default = 1 (0=daylight saving start time disabled)
P409E Daylight Saving Start Month -
Value 1-12 - Default = 10
P410E Daylight Saving Start Hour -
Value 0-23 - Default = 2
P411E Daylight Saving End Sunday -
Value 0-5 - Default = 3 (0=daylight saving end time disabled)
- - - 4 - - 7 -
Misc Option A
Duress Digit
0
Set Time HH:MM
18:23