MISCELLANEOUS PANEL OPTIONS # 1
This address (P169E) is used to select the first set of optional panel functions.
P169E 1E
Turn Off keypad LEDS at the end of exit time - Default off
2E
Keypad Panic Button delayed or instant - Default off
3E
Installer Code has direct access to Program Mode - Default on
Option 1
Turn off keypad LEDS at end of exit time
- If this option is off (LED 1 Off) then the keypad LEDS
remain working at all times. If it is on (LED 1 On), the keypad LEDS will automatically turn off at the end
of the exit delay time (NOTE: the backlight LED’s on an LED keypad will remain on). The LEDS will turn
on again if the alarm is unset, an alarm occurs or any button on the keypad is pressed.
Option 2
Keypad Panic Button delayed or instant
- If this option is off (LED 2 Off) any press of the “Panic”
button on the LED keypads will result in an immediate panic alarm. If it is turned on (LED 2 On) there will
now be a 2 second delay on the panic button. The button must be held down continuously for 2 seconds
to create a panic alarm.
Option 3
Installer Code has direct access to Program Mode -
If this option is off (LED 3 Off) the installer code
cannot gain direct access to installation program mode. Access to installation program mode in this case
must be via Client program Mode first (the owner must give authorization to the installer). If the option is
on (LED 3 On) then the installer code will allow direct access to Installation program mode provided no
areas are armed or in STAY mode.
MISCELLANEOUS PANEL OPTIONS # 2
This address (P170E) is used to select the second set of optional panel functions.
P170E 1E
Panel Tamper NC or EOL - Default off
2E
Installer Lockout - Default off
3E
Disable Mains Fail Test - Default off
4E
Arm only if sealed - Default on
5E
No audible keypad beep on supervised radio fault - Default off
6E
No audible keypad beep for zone Inactivity Timeout - Default off
7E
“Control” button disables Day Zones( CHIME ) - Default ON
8E
Silent 24 Hour Alarms (No keypad Buzzer) - Default off
Option 1
Panel Tamper NC or EOL
- The Tamper input on the PW-4 control board (Tmp) requires sealing to
clear the panel tamper alarm. If option 1 is on the panel must see a 2k2 resistor (EOL) across the Tmp &
0V terminals to ensure the tamper is sealed. If this option is turned off the a simple short circuit (NC) is
all that is required to seal the panel tamper.
Option 2
Installer Lockout
- Normally, if the panel is unset and powered up with the panel tamper open (in
alarm) then the panel will automatically go into installer program mode. If this option is on, the panel will
not automatically go into program mode and the only valid method of accessing program mode is via the
installer code.
Option 3
Disable Mains Fail Test -
If the panel must be run off a DC supply but the supply is too low to be wired
into the AC terminals then this option completely disables the mains fail monitoring so the panel will not
give a continuous system alarm.
Option 4
Arm only if sealed -
If this option is on then the panel can only be armed if all zones are sealed( Ready
LED On), with the exception of those zones which can be unsealed if programmed at address P145E.
Option 5
No audible keypad beep on supervised radio fault -
If a supervised radio detector fails to send a test
signal within a preset period, an alarm will be generated. A supervised alarm will cause the system LED
on the keypad to flash. If this option is off then all keypad buzzers will also sound continuously to warn of
the problem. If this option is on, the buzzers will not sound on a supervised alarm but the system LED
will still flash.
- - 3 - - - - -
Misc Option B