Page 23
entry delay time will apply provided a non-handover zone is triggered before the handover zone. If no other entry
delays are active when the handover zone is triggered, the zone will activate immediately.
P138E Two Trigger Zone
Zones 1-4. (Default = No zones)
This option allows programming of which zones will require two triggers before they activate. To cause an
activation a two trigger zone must alarm twice within the 2 trigger time period, P229E, or 2 two trigger zones
can alarm once each within the two trigger time period before the alarm is generated. If a two trigger zone is
unsealed and remains unsealed for a period longer than the two trigger time period, an alarm will also be
generated.
P139E Stay Mode Zone
Zones 1-4. (Default = Zone 1)
This option allows programming of which zones can be assigned as Stay Mode Zones. Only zones programmed
at this address will be active when STAY mode is armed.
P129E 24 Hour Fire Zone
Zones 1-4. (Default = No zones)
This option allows a zone to be programmed as a 24 hour fire zone. If programmed as a fire zone, when the
zone causes an alarm if will flash any outputs it is programmed to operate at a rate set by the pulse timer (P221-
228E).
P140E 24 Hour Zone
Zones 1-4. (Default = No zones)
This option allows programming of which zones can be assigned as 24 Hour Zones. Only zones programmed at
this address will be active at all times. If a 24 hour zone has an entry delay assigned to it, the entry delay acts as
an abort timer e.g. the zone must be in alarm longer than the entry delay time before the alarm is activated. If
the zone is sealed before the entry delay expires, no alarm is generated.
P141E Non-Latching 24 Hour Zone
Zones 1-4. (Default = No zones)
This option allows programming of which zones can be assigned as Non-Latching 24 Hour Zones. A Non-
Latching 24 Hour Zone will operate as a normal 24 Hour zone except that when the zone re-seals the zone LED
and any assigned outputs will reset automatically.
P142E Lockout Zone
Zones 1-4. (Default = No zones)
This option allows programming of which zones can be assigned as Lockout Zones. A Lockout Zone will only
cause the alarm output to sound once during and armed period. If the lockout function is not programmed then
the zone can cause the audible alarms to sound on every zone alarm. In the case of a 24 hour zone, if this
option is turned on then the zone will only activate the alarm output/s once and must be reset by a code before
another alarm signal can operate the output/s again.
P143E Day Zone (CHIME) when Disarmed
Zones 1-4. (Default = No zones)
This option allows programming of which zones can be assigned as Day Zones. A Day Zone can be used as a
door minder in a shop to warn when a customer has entered the premises. A day zone has the day zone
function when the alarm is disarmed, but becomes a normal security zone when armed. Day zones can be
temporarily disabled with the “Control” button if programmed to do so.
P144E Permanent Day Zone (CHIME)
Zones 1-4. (Default = No zones)
This option allows programming of which zones can be assigned as Permanent Day Zones. A Permanent Day
Zone can be used as a door minder in a shop to warn when a customer has entered the premises. A Permanent
day zone will never cause an activation when the alarm is armed). Day zones can be temporarily disabled with
the “Control” button if programmed to do so.
P145E Can Arm if not Sealed
Zones 1-4. (Default = No zones)
This option allows programming of which zones can be unsealed and still allow the panel to arm. Option 4 at
P170E must be on before this address has any effect. This option allows setting of the panel if low security
areas are not sealed at the time of arming.
P146E Report BYPASS to Dialer
Zones 1-4. (Default = All zones)
If this option is on then the zone will report any exclusion (Bypass) of the zone to a Monitoring Station via
Contact ID or 4 + 2.
P147E Send Multiple Alarms to Dialer
Zones 1-4. (Default = All zones)
If this option is assigned to the zone, the zone can send multiple activation reports to a monitoring company
during any armed cycle. If off, the zone can only send one activation per armed cycle. In the case of a 24 hour
zone, if this option is turned off then the zone will only send one signal via the dialer and must be reset by a
code before another signal can be sent.
Содержание PowerWave-4
Страница 64: ...Page 64...