43
3.3.18
Output current limitation
In order to protect the output power, the YPOWER charger / converter has an output current limitation according to the
output voltage (This function is disabled when Stabilized DC power supply is selected, curve 7 ).
3.3.19
Charging curve
When BOOST mode is ON
With this setting the YPOWER charger / converter delivers a 5-step charge curve IUoU return to automatic BOOST: BOOST,
ABSORPTION, FL REFRESH, REBOOST.
83% of Nominal output
voltage
Iout = Nominal current
10% of Nominal
Output current
Output Voltage
Output Current
42% of Nominal
output voltage