47
5
TECHNICAL
SPECIFICATIONS
Part Number
YPO12-12/60A
YPO12-24/30A
YPO12-36/15A
YPO12-48/10A
Model
12-12V/60A
12-24V/30A
12-36V/15A
12-48V/10A
Recommended battery bank *
500-700Ah
200-400Ah
100-200Ah
80-120Ah
Input
Voltage
10V -16V
10V -16V
10V -64V
10V -64V
Maximum current
65A
65A
45A
45A
Nominal Power
800W
800W
650W
570W
Efficiency
96% typical
Input fuses
3 * 25A /32V
3 * 25A /32V
3 * 20A /80V
3 * 20A /80V
Output
Number of battery bank
1
rated current
60A
30A
15A
10A
Charging curve
IU or IUoU through internal push-button or CAN-BUS (Boost, Absorption,
Floating and Refresh
–
factory setting)
Battery type
Lead sealed as factory setting - Other choices through internal setting:
gel, AGM, calcium lead, lithium, stabilized power supply, etc.
Boost voltage (default)
14.4VDC
28.8VDC
43,2VDC
57.6VDC
Floating voltage (default)
13.8VDC
27.6VDC
41,4VDC
52.2VDC
Regulation tolerance
< 2% (at rated conditions)
Peak to peak ripple and noise
< 2% (at rated conditions)
Automotive fuse
3 x 25A/32V
2 x 25A/32V
2 * 20A /80V
1 * 20A /80V
Environment
Cooling
Natural (fanless)
Operating temperature
From -20°C to +60°C, derating above 60°C.
Above 65°C, current limitation
Storage temperature
From -40°C to +70°C
Relative humidity
up to 70% (95% without condensation)
Casing
Length, height, depth / Weight
236 x 180 x 96 mm / 2.2kg
Fixing center distance
219 x 155 mm
Fixing screw (wall)
4 off M5 round head screws
Protection factor
IP22
PCB protection
Water-repellent varnish (marine environment)
Standards
CE declaration of conformity
Available on request
CE / EMC
EN61204-3
CE / Security - Others
EN60335-2-29. E-marking
E2*10R06/01*21068*00
EN60335-2-29
Protections
Polarity reversal, short-circuit, abnormal overheating
* Battery capacity recommended for lead type batteries, ratio C/10. Consult us for lithium batteries.