45
3.3.20
Indicators
The following led indicators are visible on the front of the appliance for monitoring.
INDICATORS
STATE
MEANING
Green LED 1 "ON"
On
Charger / Converter is ON
Flashing (0.1 sec. ON, 1 sec. OFF)
Charger / Converter is on Standby
Off
Charger / Converter is OFF
Internal charger / converter malfunction or
fuse is blown
Orange LED 2
"BOOST/ABSORPTION"
Flashing (1 sec. ON, 1 sec. OFF)
Charger / converter in BOOST phase
(switch E = ‘1’)
On fixed
Charger / converter in ABSORPTION phase
(switch E = ‘1’)
Green LED 2
"FLOATING/REFRESH"
On fixed
Charger / converter in FLOATING phase
Flashing (1 sec. ON, 1 sec. OFF)
Charger / converter in REFRESH phase
(switch F = ‘1’)
Off
Internal charger / converter malfunction or
output fuse blown