Crestron
e-Control
®
Software
For static IP addressing
, the commands are:
•
ADDMASTER <IP ID> < control system address>
: specifies the IP ID of
the touchpanel and the static IP address of the master control system(s). TPS
touchpanels can accept commands from up to 252 master control systems.
(If you are using the Crestron NAT and the touchpanel is located on LAN B,
then you type the LAN B address of the control system, not the LAN A
address that is visible to the outside network).
•
IPADDRESS <panel address>
: sets the static IP address of the touchpanel.
•
IPMASK <subnet mask address>
: sets the subnet mask.
•
DEFROUTER <default router IP address>
: sets the IP address of the
default router.
For example, given the following values:
IP ID 03; IP address 192.168.1.9; subnet mask 255.255.255.0; default gateway address
0.0.0.0; and control system IP address 192.168.1.1
You would type the following at the Viewport command prompt:
>ADDMASTER 03 192.168.1.1
>IPADDRESS 192.168.1.9
>IPMASK 255.255.255.0
>DEFROUTER 0.0.0.0
For dynamic IP addressing
, the commands are:
•
ADDMASTER <IP ID> <control system address/FQDN>
: specifies the IP
ID of the touchpanel and the static IP address or fully-qualified domain name
of the master control system(s). TPS touchpanels can accept commands from
up to 252 master control systems.
(If you are using the Crestron NAT and the touchpanel is located on LAN B,
then you type the LAN B address of the control system, not the LAN A
address that is visible to the outside network).
•
DHCP
ON
: enables DHCP operation.
•
HOSTNAME <name>
: specifies the hostname of the touchpanel.
•
DOMAIN <domain name>
specifies the domain. This command is only
necessary if you are configuring DHCP on an Ethernet connection to a
touchpanel that currently has a static address. The domain name will be used
to reconnect to the touchpanel after it resets. With a serial connection, the
domain does not need to be entered.
Note that the domain supplied by the DHCP server will overwrite the domain
indicated here.
•
WINS ON
specifies Windows NT 4.0 Server.
•
WINS OFF
specifies Windows 2000 Server.
Reference Guide – DOC. 6052
Crestron e-Control®
•
25
Содержание e-Control
Страница 1: ...Crestron e Control Reference Guide...
Страница 62: ...Software Crestron e Control 58 Crestron e Control Reference Guide DOC 6052...
Страница 63: ...Crestron e Control Software Reference Guide DOC 6052 Crestron e Control 59...
Страница 71: ...Crestron e Control Software This page intentionally left blank Reference Guide DOC 6052 Crestron e Control 67...
Страница 72: ......
Страница 73: ...Crestron e Control Software This page intentionally left blank Reference Guide DOC 6052 Crestron e Control 69...