Crestron
DM-RMC-100-1
DigitalMedia™ Room Controller, CAT
Connectors, Controls & Indicators (Continued)
# CONNECTORS
1
,
CONTROLS &
INDICATORS
DESCRIPTION
10
RESET
(1) miniature recessed
pushbutton, for hardware reset
11
SENS
(1) 2-pin 3.5 mm detachable
terminal block;
Digital/contact closure sensing
input;
Rated for 0-24 Volts DC,
referenced to ground;
Input impedance: 2.2k ohms
pulled up to 5 Volts DC;
Logic threshold: 2.5 Volts DC
nominal with 1 Volt hysteresis
band
12 HDMI
(1) 19-pin Type A HDMI
female;
HDMI digital video/audio
output;
Also supports DVI
7
13
USB
(1) USB Type A female;
USB 1.1 host port for
connection of a mouse,
keyboard or other USB
HID-compliant device
14 RELAY
(1-2)
(1) 4-pin 3.5 mm detachable
terminal block comprising two
normally open, isolated relays;
Rated 1 Amp, 30 Volts AC/DC;
MOV arc suppression across
contacts
(Continued on following page)
Operations & Installation Guide – DOC. 6743-2G
Room Controller, CAT: DM-RMC-100-1
•
15