
5-5
PTZ Setup Example
The figure below shows the PTZ setup Screen for Camera number 5 using a Pelco PTZ camera
with the following settings:
• Pelco P protocol
• address 1
• RS-422 communication
• 4800 baud rate
Please Note: If any one of these settings are not correct your PTZ camera will not work. Please
consult the manual that came with your camera for instructions on setting up the camera. If
after reading the manual you are still unsure of the settings, please check with the manufacturer
before calling Crest technical support.
Camera # 5 selected
Turn on PTZ function
for camera 5
Select Pelco P protocol
Comm type 422/485
Baud rate 4800
Address set to 1
After entering your camera’s settings click the save button to save the settings. Click the close but-
ton to exit the PTZ controller and the main DVR screen. Press cancel to exit without saving the
changes made to the screen.
Содержание CDVS-7000
Страница 1: ...CDVS 7000 Series DVR Setup And Users Manual Crest Electronics Inc Version 02 28 06...
Страница 8: ...Chapter 1 Overview of Main Screen 1...
Страница 21: ...Chapter 2 Search Screen Functions 2...
Страница 30: ...Chapter 3 Backing Up Data 3...
Страница 69: ...Chapter 4 System Setup 4...
Страница 95: ...Chapter 5 Setup PTZ Function 5...
Страница 104: ...Chapter 6 Backup Player 6...