![Crane Merchandising Systems BevMAX 4 Series Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/crane-merchandising-systems/bevmax-4-series/bevmax-4-series_technical-manual_2679246055.webp)
54 of 104
COMPRESSOR WILL NOT START
Compressor will not start.
Service door open.
Close service
door.
Compressor is
unplugged.
Plug
compressor in
outlet on face of
AC distribution
box.
Defective door interlock
switch.
Replace
Low voltage.
Check power
source.
Defective thermostat.
Replace.
Defective starting
component (capacitor,
relay).
Replace.
Defective compressor.
Replace.
Troubleshooting Tip:
Use a short 15 Amp extension cord and
plug the compressor directly into the wall outlet.
This will bypass the AC distribution box.
Note: For Testing Purposes Only.
Содержание BevMAX 4 Series
Страница 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Страница 53: ...52 of 104 SELECTION WILL NOT VEND Use DN Factory Diagnostics to check plunger arm replace if necessary ...
Страница 71: ...70 of 104 ...
Страница 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Страница 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Страница 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Страница 80: ...79 of 104 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Страница 82: ...81 of 104 SERVICE DOOR OUTSIDE 3 4 12 18 20 25 5 7 8B 8B 23 9 15 14 18 17 8A 21 16 13 26 19D 6 10 24 27 19B 1 ...
Страница 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Страница 96: ...95 of 104 ELECTRONICS Coke BevMax 4 EXE Control Boards 3 1 7 5 4 6 7 Executive 4 pin interface added ...
Страница 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Страница 100: ...99 of 104 ...